Ametek Surgex SA-20-AR Скачать руководство пользователя страница 26

                                           SA-20-AR                    User Manual                                                                                          

                                                                                    

______________________________________________________________________________ 

 

© 2019 AMETEK Electronic Systems Protection | Technical Support 1-800-645-9721 | surgex.com 

  25 

 

VIII.  FIRMWARE UPGRADES 

 

The AR can be upgraded via the network if the upgrade feature has been enabled. To perform a 
field upgrade, follow the steps below. 

 

Important:

  Upgrading the firmware with a minor upgrade (For example, 1.01.xx to 1.01.yy) 

will not alter the user defined settings. Major upgrades may or may not reset the AR to factory 
defaults. Check the release notes for the upgrade before making any changes. 
 

1.

 

Download the latest firmware version and Device Management Utility (DMU) from the 
SurgeX website: 

http://www.surgex.com

 

2.

 

Enable the upgrade feature. Use the CLI 

set upgrade enable yes 

command via telnet, or 

check the “Upgrade Enable” box on the Device web page. 

 

3.

 

Run the DMU. If the AR you would like to upgrade is not visible in the list box, either: 

 

 

Select Device | Discover from the menu to locate the ARs on the local network. 

 

Select Device | Add from the menu to manually add the AR by IP address. 

 

Once the device is displayed in the list, highlight it. 

 

4.

 

Select Manage | Upgrade Firmware. 

 

Enter User Name admin and the password for the Administrator. 

 

Enter the filename of the new firmware or click Browse and navigate to the firmware file 
to be used. AR firmware files use the file extension 

.g2u

. If no files of that type are 

displayed, ensure that the “Files of Type” box is set for SX-iPD or All Files. 

 

Click OK when all details are entered. 

 

5.

 

The upload will begin, and a progress bar will be displayed. 

 

6.

 

When the firmware upload is complete, the AR will automatically reboot and will be 
ready for use. 

 

IX.  RESET BUTTON 

 

The recessed reset pushbutton located on the side 
panel performs 3 functions as detailed below: 

 
 

Action 

Result 

Momentary 

Soft Reset. Will not affect outlet state. 

5 Second Push 

Reset to Factory Defaults. Hold until the “System On” LED is blinking, then release. 

Hold while powering up  Recovery Mode. Allows upload of new firmware to Factory Default IP address of 

192.168.1.254. 

 

 

Содержание Surgex SA-20-AR

Страница 1: ...l Support 1 800 645 9721 surgex com 0 Axess Ready Standalone Surge Elimination Power Conditioning SA 20 AR Firmware Version 1 20 261 Software Version 2 00 03 2019 AMETEK Electronic Systems Protection...

Страница 2: ...GEMENT UTILITY DMU 5 SETTING THE IP ADDRESS 6 V WEB SERVER 8 PASSWORD 8 CONTROL AND STATUS PAGE 8 SETUP PAGES 9 DEVICE 9 NETWORK 10 Advanced Network 11 AUTOPING 12 SCHEDULE 14 PASSWORDS 15 VI COMMAND...

Страница 3: ...s Mode surge elimination and Impedance Tolerant EMI RFI filtering Remote reboot any device monitors routers servers kiosks etc The remote device need not be network attached Conserve energy by powerin...

Страница 4: ...___________________ 2019 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com 3 Located on the top panel are Network connection RJ 45 Output receptacles Self Test LED Locat...

Страница 5: ...Connection The RJ45 connector for 10 100 Ethernet is situated on the top panel beside the output receptacles The default IP Address is DHCP assigned The fallback IP address is 192 168 1 254 3 AC Power...

Страница 6: ...ility is available on the SurgeX website at http www surgex com Note The IP address can only be set within the first 2 minutes after powering up the AR The utility will only work with ARs on the same...

Страница 7: ...Discover on This may be necessary for computers with multiple network connections Exit o Exits the DMU program Help o Online Help Opens a web browser to online help resources o About Displays DMU vers...

Страница 8: ...eboot command may be used to configure the AR to automatically acquire its network settings from a DHCP server A DHCP server will automatically assign an IP address dynamic address as well as the Subn...

Страница 9: ...rol and Status page is displayed Note Only one user may be logged in to the AR at a time Press Power On or Power Off to turn the AC output On or Off In the event of a power outage the AC output will r...

Страница 10: ...amount of time the outlet will temporarily be On or Off depending on the initial outlet state Disable Off When checked removes the Power OFF button from the Status and Control page Upgrade Enable Ena...

Страница 11: ...allow the AR to automatically acquire its network settings from a DHCP server IP Address Enter a static IP address in dotted decimal format This field will be automatically set if using DHCP Subnet M...

Страница 12: ...layed on the Goodbye page It allows use of the public IP address or DNS name instead of the internal IP address of the AR which is the default setting If this setting is left blank the hotlink will be...

Страница 13: ...ically reboots if there is no response Ideal for Kiosks and Servers Service monitor AR is installed with the device to be rebooted but pings a remote host to test the communication channel Ideal for D...

Страница 14: ...gering AR will power off and remain so until changed via web telnet or DxP Power Off Follow Upon triggering AR will power off When the ping response returns AR will power on Power Cycle Upon triggerin...

Страница 15: ...Network Time Server NTS must be specified and enabled in order to use the time scheduling feature A list of public time servers is available at http www ntp org Date Set the initial date for the event...

Страница 16: ...supports three modes of user and password operation Login Required Login with password is required for web and telnet access Auto Login No login challenge will be required for any mode of operation un...

Страница 17: ...Prompts the user to enter the user name either user or admin Password Prompts the user to enter the password Axess Ready Prompt displayed while logged in Axess Ready Reboot Required Prompt displayed...

Страница 18: ...address Yes 192 168 1 254 set subnet dotted decimal Sets the Subnet Mask Yes 255 255 255 0 set gateway dotted decimal Sets the Gateway address Yes 192 168 1 1 set http port 0 65535 Sets the port that...

Страница 19: ...ess to be pinged for AutoPing 1 or 2 Yes 0 0 0 0 set autoping 1 2 frequency 1 999 Sets the frequency how often the ping is sent for AutoPing 1 or 2 in seconds Yes 10 set autoping 1 2 failcount 1 999 S...

Страница 20: ...mple Current Time 10 14 17 12 20 2011 Server 10 1 2 12 Ok No set time server dotted decimal Sets the IP address of a Network Time Server Yes 64 90 182 55 set time enable yes no Enables or disables the...

Страница 21: ...bers to allow for advanced security when AES encryption is used With AES enabled all messages must be encrypted with the AES Passphrase set in the device After the Hello a Command and Response sequenc...

Страница 22: ...lasses uName Reserved for future use It will contain the user name of a user on the ipIO that is being accessed password Reserved for future use It will contain the password of the user above desc Com...

Страница 23: ...from the server 3 eCmnd_io This command is used to monitor and control the I O on the server 4 eCmnd_keepAlive This command is sent to the server as a means of allowing the client to validate the com...

Страница 24: ...geRelays payload see the Payloads subsection for details 0 Successful 1 Error eIO_getRelay This command has not yet been implemented eIO_getRelays This command is used to get the status of all the rel...

Страница 25: ...he relay 1 Energize 2 Relax o TChangeRelays typedef struct unsigned char relayStates 32 TChangeRelays Where relayStates is an array of relay states as defined below define NO_CHANGE 0 define ENERGIZE...

Страница 26: ...x either Select Device Discover from the menu to locate the ARs on the local network Select Device Add from the menu to manually add the AR by IP address Once the device is displayed in the list highl...

Страница 27: ...industry standard rating Maximum Applied Surge Pulse Current Unlimited due to current limiting 8 x 20 s Endurance IEEE C62 41 1991 Category B3 C1 Pulses 1 kV 500 000 3 kV 10 000 6 kV 1000 EMI RFI Fil...

Отзывы: