Event Commands
Command
Description
Admin
Fact Def
get events
Returns all scheduled events currently in use. Example:
Date Time Repeats Action
1. 12/22/2011 14:00 every 2 Hour(s) Cycle
2. every 0 Day(s) On
3. every 0 Day(s) On
4. every 0 Day(s) On
5. every 0 Day(s) On
6. every 0 Day(s) On
7. every 0 Day(s) On
8. every 0 Day(s) On
Ok
No
get time
Returns the current time and time server. Example:
Current Time: 10:14:17 12/20/2011
Server: 10.1.2.12
Ok
No
set time server < dotted decimal >
Sets the IP address of a Network Time Server.
Yes
64.90.182.55
set time enable < yes | no >
Enables or disables the use of a time server and scheduled events.
Yes
No
set event < 1-8 > date < mm/dd/yyyy >
Sets the scheduled event’s starting date.
Yes
set event < 1-8 > time < hh:mm:ss >
Sets the time the scheduled event will occur in 24-hour format.
Yes
set event < 1-8 > repeat < day | hour | minute >
Sets the repetition interval type for the selected event.
Yes
set event < 1-8 > mult < 0-999 >
Sets the number of repetition intervals for the selected event. For
example, 20 days, 30 minutes, 24 hours, etc.
Yes
set event < 1-8 > action < on | off | cycle >
Sets the action to be performed at the scheduled time.
Yes
del event < 1-8 >
Deletes the scheduled event.
Yes