![Ametek SURAGEX AXESS Reasy FLATPAK SA-82-AR Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/ametek/suragex-axess-reasy-flatpak-sa-82-ar/suragex-axess-reasy-flatpak-sa-82-ar_hardware-installation-manual_2931339026.webp)
© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
25
SA-82-AR User Manual
_____________________________________________________________________________________________
X. Specifications
Physical
Height
1.812
5”
Width
11.37
5”
Depth
7.625
”
Weight
4.75 lb.
Temperature
5 - 35° C
Humidity Range
5% to 95% R.H., non-condensing
AC
Load Rating
8 Amps @ 120 Volts
Power Requirement (no load)
10 Watts
UL 1449-2 Adjunct Classification
Test Results
1000 surges, 6000 Volts, 3000 Amps,C1 pulse, measured
suppressed voltage 290 Volts, no failures
Maximum Applied Surge Pulse
Joule Rating
Unlimited, due to current limiting (8 x 20 µs)
Maximum Applied Surge Pulse
Voltage
6000 volts (1.2 x 50 µs pulse),industry standard rating
Maximum Applied Surge Pulse
Current
Unlimited, due to current limiting (8 x 20 µs)*
Endurance
IEEE C62.41-1991 Category B3 (C1)
Pulses
1 kV>500,000; 3 kV>10,000; 6 kV>1000
Overvoltage Shutdown
145 Volts (resume at 135 Volts)
EMI/RFI
Filter
Normal Mode (50
Ω
load)
30 dB@100 kHz; 56 dB@300 kHz;64 dB@3 MHz;
24 dB@30 MHz
Common Mode (50
Ω
load)
9 dB@300 kHz; 16 dB@1 MHz;28 dB@5 MHz;
35 dB@20 MHz
Compliance
UL/cUL
UL60950 Listed I.T.E. File
No. E225914
Conforms to UL Stds 1283 & 1449
CSA
Certified to CSA Std C22.2 No. 8
CE
Directives 89/336/EEC, 92/31/EEC and 93/68/EEC EN 60950:
3
rd
Edition
EN55022: 1998 Class B
FCC
Part 15 Class B
Network
Single 10/100 Unshielded Twisted Pair Ethernet Jack
IP Addressed: DHCP Assigned or Static
Internal HTTP Web Server
Forms Processing Browser Required
Internal Telnet Server
*1.2 x 50 µs pulse, industry standard combination wave surge,as per IEEE C62.41