                                                                             SA-82-AR                              User Manual 

       ________________________________________________________________________________________________

 

 

 

4.   

Commands

 

 

There are currently 7 command classes. All classes are defined in the C programming enumerated type 

definition below: 

 

typedef enum { eCmnd_null, 

eCmnd_set, 

eCmnd_get, 
eCmnd_io, 

eCmnd_keepAlive, 

eCmnd_rss, 

eCmnd_rcu 

} eCmnd; 

 

 

 

 

Command

 

Description

 

0

 

eCmnd_null

 

This is a null command and should not be sent to the server.

 

1

 

eCmnd_set

 

This command is used to set programmable variables on the server.

 

2

 

eCmnd_get

 

This command is used to get programmable variables from the server.

 

3

 

eCmnd_io

 

This command is used to monitor and control the I/O on the server.

 

4

 

eCmnd_keepAlive

 

This command is sent to the server as a means of allowing the client to 

validate the communications path to the server.

 

5

 

eCmnd_rss

 

This command class is used to control the RSS nest using the 

RCU. 

Note: Project specific command. Not for general use.

 

6

 

eCmnd_rcu

 

This command class is used to update the display of the RCU. 

Note: Project specific command. Not for general use.

 

 

 

 

 

5. 

Descriptors

 

 

Descriptors are used to describe the individual command within a command class, and the payload that the 

packet contains. All of the descriptors and their payloads are outlined by command class below. 

 

eCmnd_set 

The descriptors for this command class will be product specific. 

 

eCmnd_get 

The descriptors for this command class will be product specific. 

Содержание SURAGEX AXESS Reasy FLATPAK SA-82-AR

Страница 1: ...SA 82 AR Hardware Installation Guide FIRMWARE VERSION 1 20 261 SOFTWARE VERSION 2 00 03 2019 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 UM SA 82 AR Rev D...

Страница 2: ...TING THE IP ADDRESS 5 IV OUTLET ON LED INDICATOR 6 V WEB SERVER 7 1 PASSWORD 7 2 CONTROL AND STATUS PAGE 7 3 SETUP PAGES 8 DEVICE 8 NETWORK 9 ADVANCED NETWORK 10 AUTOPING 11 SCHEDULE 13 PASSWORD 14 VI...

Страница 3: ...tors routers servers kiosks etc The remote device need not be network attached Conserve energy by powering down equipment when not in use Telnet access uses the Command Line Interface CLI structure an...

Страница 4: ...load of all controlled devices does not exceed 8 Amps Connect one end of the supplied power cord to the connector labeled AC Input and the other end to a properly grounded AC outlet 3 LED Indicators...

Страница 5: ...gement Utility is available on the SurgeX website at http www surgex com Note The IP address can only be set within the first 2 minutes after powering up the AR The utility will only work with ARs on...

Страница 6: ...to Discover on This may be necessary for computers with multiple network connections Exit Exits the DMU program Help Online Help Opens a web browser to online help resources About Displays DMU versio...

Страница 7: ...lly assign an IP address dynamic address as well as the Subnet Mask and Gateway To determine what IP address has been automatically assigned by the DHCP server you will need to use the Discover featur...

Страница 8: ...the Control and Status page is displayed Note Only one user may be logged in to the AR at a time Press Power On or Power Off to turn the AC output On or Off In the event of a power outage the AC outpu...

Страница 9: ...n or Off depending on the initial outlet state Disable Off When checked removes the Power OFF button from the Status and Control page Initial State Specifies the initial state the AC outlet s will ass...

Страница 10: ...CP to allow the AR to automatically acquire its network settings from a DHCP server IP Address Enter a static IP address in dotted decimal format This field will be automatically set if using DHCP Sub...

Страница 11: ...link displayed on the Goodbye page It allows use of the public IP address or DNS name instead of the internal IP address of the AR which is the default setting If this setting is left blank the hotlin...

Страница 12: ...omatically reboots if there is no response Ideal for Kiosks and Servers Service monitor AR is installed with the device to be rebooted but pings a remote host to test the communication channel Ideal f...

Страница 13: ...Off Follow Upon triggering AR will power off When the ping response returns AR will power on Power Cycle Upon triggering AR will cycle the power AR will then wait for Ping Frequency x Fail Count secon...

Страница 14: ...t A Network Time Server NTS must be specified and enabled in order to use the time scheduling feature A list of public time servers is available at http www ntp org Date Set the initial date for the e...

Страница 15: ...of the AR Passwords may be up to 20 characters long and are case sensitive The AR supports three modes of user and password operation Login Required Login with password is required for web and telnet...

Страница 16: ...pt displayed while logged in Axess Ready Reboot Required Prompt displayed after changes have been made that require a reboot This prompt will remain active until the AR has been rebooted 2 Control Com...

Страница 17: ...et dotted decimal Sets the Subnet Mask Yes DHCP set gateway dotted decimal Sets the Gateway address Yes DHCP set http port 0 65535 Sets the port that the internal Web server listens for incoming conne...

Страница 18: ...ber of consecutive failures the AutoPings must detect before the AutoPing considers the pinged device to be failed Yes 3 set autoping mode single and or Sets single AutoPing AutoPing 1 or two AutoPing...

Страница 19: ...2011 Server 10 1 2 12 No set time server dotted decimal Sets the IP address of a Network Time Server Yes 64 90 182 55 set time enable yes no Enables or disables the use of a time server and scheduled...

Страница 20: ...ence numbers to allow for advanced security when AES encryption is used With AES enabled all messages must be encrypted with the AES Passphrase set in the device After the Hello a Command and Response...

Страница 21: ...command classes uName Reserved for future use It will contain the user name of a user on the ipIO that is being accessed password Reserved for future use It will contain the password of the user above...

Страница 22: ...variables from the server 3 eCmnd_io This command is used to monitor and control the I O on the server 4 eCmnd_keepAlive This command is sent to the server as a means of allowing the client to valida...

Страница 23: ...he TChangeRelays payload see the Payloads subsection for details 0 Successful 1 Error eIO_getRelay This command has not yet been implemented eIO_getRelays This command is used to get the status of all...

Страница 24: ...IZE 1 define RELAX 2 This payload is supported by devices that support the DxP protocol with 2 32 controllable relays TPulseRelay typedef struct unsigned char relay the relay to be pulsed unsigned cha...

Страница 25: ...the list highlight it 4 Select Manage Upgrade Firmware Enter User Name admin and the password for the Administrator Enter the filename of the new firmware or click Browse and navigate to the firmware...

Страница 26: ...pulse industry standard rating Maximum Applied Surge Pulse Current Unlimited due to current limiting 8 x 20 s Endurance IEEE C62 41 1991 Category B3 C1 Pulses 1 kV 500 000 3 kV 10 000 6 kV 1000 Overvo...

Отзывы: