Local Operation
User Diagnostics
64
Operating Manual for XHR Series Power Supply
User Diagnostics
If your power supply is not performing as described in this manual, run through the
procedures and checks in this section before calling your service technician. These
procedures are confined to operator-level functions only and do not require cover-off
servicing.
Emergency
Shutdown
In an emergency, carry out both of these steps:
1. Shut the power supply off immediately.
2. Disconnect the power supply from the load.
Unusual or
Erratic
Operation
If the power supply displays any unusual or erratic operation, follow these steps:
1. Shut the power supply off immediately.
2. Disconnect the power supply from the load.
3. Test the power supply with no load, running the tests in “Functional Tests” on
4. If the tests show that the power supply is functioning normally, check that load,
programming, and monitoring connections and circuits.
5. Check the AC input for correct voltage and frequency.
If the problem is not solved by following this procedure, or if the unit fails to operate
correctly upon retesting, call your service technician.
Troubleshooting
for Operators
Use the checks in
Table 3.4, “Quick Diagnostics”
to ensure that the power supply is
configured and connected for normal operation. If you require further
troubleshooting, call your service technician.
Abbreviated References Used in Table
ACF
AC Fail
OTP
over temperature protection
OVP
over voltage protection
REM
remote mode
S/D
shutdown
Содержание Sorensen XHR 100-10
Страница 2: ......
Страница 4: ...This page intentionally left blank ii ...
Страница 6: ...This page intentionally left blank iv ...
Страница 8: ...This page intentionally left blank vi ...
Страница 12: ...List of Figures x Operating Manual for XHR Series Power Supply ...
Страница 14: ...List of Tables xii Operating Manual for XHR Series Power Supply ...
Страница 47: ...Installation Load Connection 47 Figure 2 9 Multiple Loads with Remote Sensing ...