Features and Specifications
Specifications
25
Table 1.3
Electrical Specifications for 60 V to 600 V Models
Models
60-18
100-10
150-7
300-3.5
600-1.7
Output Ratings:
Output Voltage
Output Current
Output Power
0-60 V
0-18 A
1080 W
0-100 V
0-10 A
1000 W
0-150 V
0-7 A
1050 W
0-300 V
0-3.5 A
1050 W
0-600 V
0-1.7 A
1020 W
Line Regulation:
1
Voltage (0.01% of Vmax + 2 mV)
Current (0.01% of Imax + 1 mA)
1. For input voltage variation over the AC input voltage range, with constant rated load.
8 mV
2.8 mA
12 mV
2 mA
17 mV
1.7 mA
32 mV
1.3 mA
62 mV
1.2 mA
Load Regulation:
2
Voltage (0.01% of Vmax + 2 mV)
Current (0.05% of Imax + 1 mA)
At the front panel binding posts:
Voltage
2. For 0-100% load variation, with constant nominal line voltage. Measured at the rear panel output connector unless
stated otherwise.
8 mV
10 mA
400 mV
12 mV
6 mA
300 mV
17 mV
4.5 mA
200 mV
32 mV
3 mA
100 mV
62 mV
2 mA
62 mV
Meter Accuracy:
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
0.7 V
0.19 A
1.1 V
0.11 A
1.6 V
0.08 A
4 V
0.05 A
7 V
0.03 A
Output Noise and Ripple (V):
rms
p-p (0-20MHz)
At the front panel binding posts:
p-p (0-20MHz)
10 mV
75 mV
400 mV
10 mV
100 mV
400 mV
20 mV
150 mV
450 mV
30 mV
250 mV
500 mV
120 mV
500 mV
700 mV
Drift (8 hours):
3
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
3. Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
30 mV
18 mA
50 mV
10 mA
75 mV
7 mA
150 mV
3.5 mA
300 mV
1.7 mA
Temperature Coefficient:
4
Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)
4. Change in output per °C change in ambient temperature, with constant line and load.
12 mV
5.4 mA
20 mV
3 mA
30 mV
2.1 mA
60 mV
1.1 mA
120 mV
0.48 mA
Maximum Remote Sense
Line Drop Compensation
5
5. Line drop is subtracted from total voltage available at supply output.
5 V/line
5 V/line
5 V/line
5 V/line
5 V/line
OVP Adjustment Range
(5% to 110% of Vmax)
3-66 V
5-110 V
7.5-165 V
15-330 V
30-660 V
Efficiency
6
6. Typical efficiency at 115 Vac input and rated output power.
84%
84%
85%
85%
85%
Содержание Sorensen XHR 100-10
Страница 2: ......
Страница 4: ...This page intentionally left blank ii ...
Страница 6: ...This page intentionally left blank iv ...
Страница 8: ...This page intentionally left blank vi ...
Страница 12: ...List of Figures x Operating Manual for XHR Series Power Supply ...
Страница 14: ...List of Tables xii Operating Manual for XHR Series Power Supply ...
Страница 47: ...Installation Load Connection 47 Figure 2 9 Multiple Loads with Remote Sensing ...