background image

10

Manual Part No. 502923 Issue 3

6.0:  PIE / Probe Connections

6.0: PIE / Probe Connections

6.1: PIE / Probe Connections (continued) 

M5 Circular Connector

To separate the probe and PIE, hold the probe 

connector and turn the locking ring only. When the 

locking ring is fully unscrewed the connector halves 

may be separated. Excessive cable twist may cause 

damage.

6.2: Grounding / Shielding

 

Pin to Pin Connection

It is recommended that the spade terminal be connected 

to the same metal work as the transducer. When multiple 

Mini Probes are being used, only one connection may 

be required. For installations where the PIE module and 

the probe are mounted close to each other on common 

metalwork, this extra connection may not be required.

The unshielded wires from the transducer should remain 

loosely twisted and be contained within (or remain in close 

proximity to) the metalwork.

These precautions will greatly improve the grounding / 

shielding aspects of the installation.

M5 Circular Connector

No additional screening precautions are required. The 

cable screens are continuous through the connector.

For additional advice regarding grounding and shielding, 

contact your original supplier.

Probe Connector

PIE Connector

Locking Ring

Содержание Solartron Metrology Digital Mini Probe

Страница 1: ...1 Manual Part No 502923 Issue 3 user leaflet DIGITAL MINI PROBE ...

Страница 2: ...6 5 2 Mounting 6 5 3 Cable 7 5 5 Tip Adjustment 8 5 6 Tip Replacement 8 6 0 PIE Probe Connections 9 6 1 PIE Probe Connections 9 6 2 Grounding Shielding 10 Section Title Page 7 0 Specifications 11 8 0 Outline Drawings 12 8 1 Outline Drawings DM 05 S 12 8 2 Outline Drawings DM 1 S 13 Return of Goods Solartron Sales Offices 1 0 Index 2 Manual Part No 502923 Issue 3 ...

Страница 3: ...ere applicable cautionary or other information is to be found WARNINGS Do not operate in an explosive atmosphere To avoid explosion do not operate this equipment in an explosive atmosphere This equipment is not intended for use in a safety critical environment NOTES This equipment contains no user serviceable parts This equipment must be returned to your original supplier for all servicing and rep...

Страница 4: ...ng applications such as automatic gauges The parallel spring also insures a high level of repeatability both on axis and across axis so that it can be used in dynamic applications where profiling is required The Digital version of the Mini Probe along with other digital products can be connected to a PC or PLC via the Orbit Network system or directly to a digital readout CAUTION The Mini Probe nee...

Страница 5: ...5 Manual Part No 502923 Issue 3 4 0 Components of the Mini Probe 4 0 Components of the Mini Probe Location of M3 Mounting Screw Adjustable Tip Fluoroelastomer Boot Mounting Face ...

Страница 6: ...ini Probe The probe head may be mounted in any orientation To ease installation the Mini Probe head can be disconnected from the PIE It is important that the PIE with the correct ident is used with the corresponding Mini Probe head To maximise service life and to minimise the potential for accidental damage the following points need to be considered Set probe height to minimise the amount of defle...

Страница 7: ...en a minimum bend radius of 150 mm should be maintained A minimum bend radius of 1 mm is recommended for the wires coming out of the probe head These wires should not be subjected to regular bending If a cable is damaged it is not possible to repair it without affecting the probe calibration The complete assembly Mini Probe and PIE must be replaced WARNING When mounting the Mini Probe in a fixture...

Страница 8: ... Mini Probe frame so that it is not stressed during the tip removal 2 Using the spanner supplied unscrew the tip from the Mini Probe To install tip 1 Firmly hold the Mini Probe frame so that it is not stressed during the tip installation 2 Using the spanner supplied screw the replacement tip into the Mini Probe until the required tip extension is achieved The tip is self locking so a tightening to...

Страница 9: ... push the pin and socket together feeling for the pin and socket making contact before finally pushing them together Alternatively slide the sleeve back to expose the connector Push the pin and socket together and then slide the sleeve back into position Gently pull the ends of the sleeve to stretch it slightly This puts a little tension into the sleeve and helps to pull the connector pins togethe...

Страница 10: ...ple Mini Probes are being used only one connection may be required For installations where the PIE module and the probe are mounted close to each other on common metalwork this extra connection may not be required The unshielded wires from the transducer should remain loosely twisted and be contained within or remain in close proximity to the metalwork These precautions will greatly improve the gr...

Страница 11: ...11 Manual Part No 502923 Issue 3 7 0 Specification See Orbit3 Catalogue 7 0 Specification For instruction on using Orbit3 see the Orbit3 System Manual supplied on the Orbit3 Support Pack for Windows CD ...

Страница 12: ...12 Manual Part No 502923 Issue 3 8 0 Outline Drawings 8 0 Outline Drawings Standard Product tip and specifications may vary 8 1 Mechanical Drawing DM 05 S ...

Страница 13: ...13 Manual Part No 502923 Issue 3 8 0 Outline Drawings 8 0 Outline Drawings Standard Product tip and specifications may vary 8 2 Mechanical Drawing DM 1 S ...

Отзывы: