ReFlex Power™
AC Power Supplies
M380056-01 Rev L
4-57
4.6.11
C
URRENT
ADC
O
FFSET
C
ALIBRATION FOR
V
OLTAGE
R
ANGE
H
IGH
The following procedure calibrates offset of the current ADC for the voltage range
high.
1. Ensure that no load is connected to the output.
2. Issue clear and reset commands:
*CLS
*RST<n>
3. Set the voltage range of the power supply to high
SOUR<n>:VOLT:RANGE 1
4. Perform the voltage ADC offset calibration
CAL<n>:MEAS:IADC:OFFSET:CALC
5. Send the system error query command to make sure calibration was successful.
SYST:ERR?
6. If there is no error returned at the system error query command then save the
calibration result with the following command
CAL<n>:UNLOCK “6867”
CAL<n>:STORE
CAL<n>:LOCK
7. Optional Commands
To query the voltage ADC offset:
CAL<n>: MEAS:IADC:OFFSET ?
8. Reset the unit
*RST<n>
Содержание Elgar ReFlex Power
Страница 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii This page intentionally left blank...
Страница 8: ...iv This page intentionally left blank...
Страница 10: ...vi This page intentionally left blank...
Страница 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Страница 22: ......
Страница 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Страница 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Страница 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Страница 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Страница 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Страница 173: ...Fixed Power DC Power Supply ReFlex Power 5 4 M380056 01 Rev L Figure 5 2 Rear View of Typical DC Supply Module...
Страница 260: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 57 Figure 6 22 Series Parallel Output Configuration...
Страница 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Страница 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Страница 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Страница 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Страница 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Страница 292: ...ReFlex Power Active Loads M380056 01 Rev L 7 17 Figure 7 5 Slot Numbering Assignment Empty Mainframe Front View...
Страница 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...