29
Instruction Manual/Betriebsanleitung
BG75SI
, Version: 1.1 en_de
© 2011 Dunkermotoren GmbH; D-79848 Bonndorf; Germany
9.6 Function of the pulse output OUT1
The pulse output OUT1 provides 12 impulses per motor
turn, whereas the pulse duration t
P
and the pulse brake
t
0
is motor speed addicted. As a result of the generation
of the pulses via sampling, a fuzziness of up to 100 ms
arises at the flanks, so that a measurement of the pulse
duration larger than 1 pulse is not adequate for desi-
gnation of the motor speed. The pulse duration t
P
and
the pulse brake t
0
are at the same length on average.
Thereby, approximately following correlation is essenti-
al at a rotation of n rpm:
The output is performed as PNP-transistor 24 V plus
switching, with a max. permitted current strain of 250
mA.
9.6 Funktion des Pulsausgangs OUT1
Der Pulsausgang OUT1 liefert 12 Impulse pro Motor-
umdrehung, wobei die Pulsdauer t
P
und die Pul-
spausendauer t
0
drehzahlabhängig ist. Aufgrund der
Erzeugung der Impulse durch Abtastung ergibt sich
bei den Flanken eine Unschärfe von bis zu 100 ms,
so dass eine Pulsdauermessung über 1 Impuls nicht
zur Drehzahlbestimmung geeignet ist. Die Pulsdauer
t
P
und die Pulspausendauer t
0
sind im Mittel gleich
lang. Dabei gilt bei einer Umdrehungszahl von n rpm
ungefähr folgender Zusammenhang:
Der Ausgang ist als PNP-Transistor 24 V-plusschal
-
tend mit einer max. zulässigen Strombebelastung von
250 mA ausgeführt.
12 pulses comply with 1 motor rotation
12 Impulse entspricht 1 Motorumdrehung
t
P
= (2000 / n) ms