MX15 Series
63
4.1.3 Status Indicator Lights
Five LED status indicators are located to the left of the LCD display. These LED’s correspond to
the following conditions:
REMOTE
The REMOTE LED indicates that the unit is in remote control
mode. If the IEEE-488 interface is used, this indicator will be lit
whenever the REM line (REMOTE ENABLE) line is asserted by
the IEEE controller. If the RS232, USB or LAN interface is used,
the REMOTE state can be enabled by the controller using the
SYST:REM command. Any time the REMOTE LED is lit, the
front panel of the MX Series unit is disabled. The BACK key
doubles as a LOCAL button that allows the user to regain
control of the front panel.
OVERLOAD
The OVERLOAD LED indicates an output overload condition.
This condition can be controlled by setting the current limit
value in the PROGRAM menu. Removing the load using the
OUTPUT ON/OFF button will recover from an overload
condition.
OVER TEMPERATURE
The OVER TEMPERATURE LED indicates an overheating
problem inside the unit. This is an abnormal condition, which
will cause the unit to shut off. Check the air openings to make
sure they are not blocked.
HI RANGE
The HI RANGE LED is on when the high voltage output range
has been selected.
OUTPUT
The OUTPUT LED is on when the output relay is closed.
Содержание California Instruments MX15 Series
Страница 1: ...7005 960 Rev N www programmablepower com MX15 Series AC and DC Power Source User Manual...
Страница 29: ...MX15 Series 29 Figure 2 5 MX output filter option schematic...
Страница 30: ...30 Figure 2 6 MX15 Output Noise 10 KHz 1 MHz...
Страница 31: ...MX15 Series 31 Figure 2 7 MX45 Output Noise 10 KHz 1 MHz with Optional Filter...
Страница 34: ...34 Figure 3 2 Location of AC Input Fuse Block and Chassis Ground Connection Rear View Access Panel Removed...
Страница 36: ...36 Figure 3 3 MX Series AC Input Connection Diagram Rear view...
Страница 43: ...MX15 Series 43 Figure 3 8 Two MX s in Clock and Lock mode Output Wiring Rear view...
Страница 45: ...MX15 Series 45 Figure 3 10 Three MX s in Clock and Lock mode Output Wiring Rear view...
Страница 58: ...58 Figure 3 15 Functional Test Setup...
Страница 106: ...106 Figure 5 2 MX Series Detailed Block Diagram...
Страница 107: ...MX15 Series 107 Figure 5 3 Power Module Detailed Block Diagram...
Страница 111: ...MX15 111 Figure 5 5 Amplifier Board Layout...
Страница 139: ...MX15 139 Figure 9 4 Voltage Modulation Frequency characteristics...