Page 27
User Guide
LSP
HD
Linescanner Head
Scan Line Separation = Product Speed m / ft
Scan Frequency
When you have determined the required scan frequency, choose the scan rate that
either closely matches or exceeds the required rate.
It is not good practice to simply select the scanner's maximum scan rate regardless of
process requirements. The reasons for this are outlined below:
Parameter
High Speed
Low Speed
Scan line separation
Closely spaced
Widely spaced
Lateral resolution
Lower resolution
Higher resolution
Disk space for file storage
Greater space required
Less space required
Processor requirements
Higher
Lower
6.4 Data Storage Requirements
Data is generated at a rate of approximately 2.5 kB per scan line, with a minimum
requirement of 440 kB for file headers. Therefore, at a scan frequency of 50 Hz, each
one minute measurement period will require 7.94 MB of data storage space.
Landscan WCA software allows you to select a reduced number of lines for storage (see
the Landscan WCA Software Online Help).
Product speed m/s
or ft/s
S
ca
n li
ne
Scan line separation
6.3 Scan Line Separation
Содержание 0 LAND LSP HD 61
Страница 4: ...Blank...