8-6 Revised October 31, 2005
193111-068
PROGRAMMING YOUR UC2000 CONTROL
Multi AmpHour Programming Your
UC2000 Control
The Multi AH Feature of the UC2000 Control allows the
user to customize his Ultra Charge to fit his multi–
battery application. Using this feature, the flexibility of
the Ultra Charge can be used to charge batteries of
different Amp Hour capacities and types without using
Battery Identification Modules (BIDs) or different
chargers with different plug types.
The control can be programmed to charge different
voltage batteries with the AH rates and curve types that
have been programmed for that battery voltage. When
a battery is connected, the control automatically senses
the battery voltage and sets the charge curve and
charging rates to the level that has been programmed.
The Multi AH functions are programmed through a
separate menu item on the control. Complete steps for
programming a typical application are listed to the right.
Application
6 cell, 450AH Gel Type Maintenance Free
12 cell, 680AH Flooded
18 cell, 744AH Flooded
750T3-18 Ultra Charge
With the control programmed as shown to the right, the
control will charge any 6 cell battery that is connected
to the charger at the proper 450AH rates for a
Deka
Dominator
Sealed Gel Battery. Any 12 cell battery con-
nected to the charger will be charged at the proper
680AH rates for a standard flooded battery. Finally,
any 18 cell battery connected to the charger will be
charged at the proper 744AH rates for a standard
flooded battery.
By enabling the Multi AH function, any 6,9,12,18,24,
and/or 36 cell battery that is equal to or less than the
charger rated voltage can be charged at a unique AH
rate and with a unique charge curve. For example,
750T3-24 can be programmed to charge 6,9,12,18 and
24 cell batteries with different AH rates and/or different
charge curves.
Key Entry Display
ULTRA CHARGE
Program Review
Menu Tree 1 – 4
3
Multi AH Mode OFF
Enter
Multi AH Mode OFF
▲
Multi AH Mode ON
Enter
Multi AH Mode ON
▼
6 Cell Amphrs 0750
Enter
6 Cell Amphrs 0750
0450
6 Cell Amphrs 0450
Enter
6 Cell Amphrs 0450
▼
6 Cell Battype
►
FLD
Enter
6 Cell Battype
►
FLD
4
6 Cell Battype
►
DSG
Enter
6 Cell Battype
►
DSG
▼
9 Cell Amphrs 0750
▼
9 Cell Battype
►
FLD
▼
12 Cell Amphrs 0750
Enter
12 Cell Amphrs 0750
0680
12 Cell Amphrs 0680
Enter
12 Cell Amphrs 0680
▼
12 Cell Battype
►
FLD
▼
18 Cell Amphrs 0750
Enter
18 Cell Amphrs 0750
0744
18 Cell Amphrs 0744
Enter
18 Cell Amphrs 0744
▼
18 Cell Battype
►
FLD
Program Review
Menu Tree 1 – 4
Program Review
ULTRA CHARGE
Содержание ULTRA CHARGE
Страница 17: ...6 4 March 31 2005 193111 068 OPERATION ULTRA CHARGE RECHARGING CAPABILITY Figure 6 1 ...
Страница 29: ...193111 068 UC2000 CONTROL FEATURES 7 12 Revised October 31 2005 Figure 7 2 ...
Страница 37: ...193111 068 PROGRAMMING YOUR UC2000 CONTROL 8 8 Revised August 30 2005 Figure 8 1 ...
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......