Page 9

For technical questions, please call 1-888-866-5797.

Item 64017

Sa

F

ety

Opera

ti

O

n

Maintenance

Setup

Backlight and Worklight

1�  Press the 

B.L HOLD

 button for 

two or more seconds to turn on the 
LCD backlight for 30 seconds�

2�  Press the 

B.L HOLD

 button for 

two or more seconds again to 
turn the LCD backlight off�

3�  While in current range modes, 

turning the backlight on also 
turns the clamp Worklight on�

note:

 Frequent use of the backlight will 

shorten the life of the batteries� Only 
use the backlight when necessary�

Data Hold

The data hold function keeps the current reading on the Display� To activate data hold:

1�  Press the 

B.L HOLD

 button and 

the reading will be held on the 
Display� The 

 

symbol appears�

2�  Press 

B.L HOLD

 again 

to release the hold�

ncV (non-contact Voltage)

1�  Turn Rotary Switch to 

the 

ncV

 position�

2�  Move the tip of the clamp close to the 

unshielded conductor�  If detected 
voltage is >110V AC,

 

Meter will beep 

and the NCV Indicator will flash�

WarninG!

 

even if no indication is 

given, voltage may still be present.

   

Do not rely solely on NCV detection to 
determine the presence of voltage�

auto power-Off

If the Meter is not used for approximately 15 minutes, it will automatically turn itself off 
to conserve battery power� To turn the Meter back on after auto-off, press the 

Func

 

button� To disable Auto Power-Off, hold the 

Func

 button while powering the Meter on�

Содержание 1000a

Страница 1: ...ence 17i When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All...

Страница 2: ...sed to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will resul...

Страница 3: ...them c The battery is low d Near any explosive gasses or fumes e Any abnormal operation is detected If in doubt about the condition of the Meter have it serviced before use f The battery cover is ope...

Страница 4: ...e diodes or continuity disconnect all power to the circuit and discharge all high voltage capacitors 23 Performance of this Meter may vary depending on battery condition 24 Use the proper settings ter...

Страница 5: ...Hz Inrush Current Accuracy 0A 60A Reference only 600A 1000A 5 0 of rdg 60D Resistance Ranges 600 6k 60k 600k 6M 60M Resistance Accuracy 600 600k 0 8 of rdg 3D 6M 60M 2 0 of rdg 5D Continuity Meter bee...

Страница 6: ...iOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions current clamp rotary Switch Function Button Backlight reading Ho...

Страница 7: ...Power Off autO Auto range mode inr Inrush mode Continuity Diode test reL Relative measurement mode ncV Non contact voltage detection MaX The maximum value is being measured Min The minimum value is b...

Страница 8: ...utton to return to auto range note Manual range cannot be used while measuring frequency Frequency and Duty cycle Measurements 1 While working with voltage or current ranges press the Hz button one ti...

Страница 9: ...isplay To activate data hold 1 Press the B L HOLD button and the reading will be held on the Display The symbol appears 2 Press B L HOLD again to release the hold ncV non contact Voltage 1 Turn Rotary...

Страница 10: ...tions note When using manual range mode always start with the highest range if the amperage is unknown note Center conductor between guides in Clamp jaws as shown ac Dc current Measure AC and DC condu...

Страница 11: ...to OFF and store Meter note If the Display shows OL while in manual range mode the measurement has exceeded the selected range A higher range should be selected ac Dc Voltage Measurement Measure AC co...

Страница 12: ...on the Display 5 When testing is complete turn Rotary Switch to OFF and store Meter note Current test range is 10Hz 1kHz in Voltage Frequency Mode 1 Plug black test lead into cOM Jack Plug red test le...

Страница 13: ...r This is due to the Meter s output test current going through all possible paths between leads note For resistance measurements above 1M allow a few seconds to get a steady reading note When leads ar...

Страница 14: ...s cathode 5 Read measured forward biased voltage drop on the Display note If the test leads are reversed or open OL is displayed 6 When testing is complete turn Rotary Switch to OFF remove Test Leads...

Страница 15: ...tion 4 Other than the batteries there are no replaceable parts on this unit repairs should be done by a qualified technician Battery replacement If the sign appears on the Display the battery should b...

Страница 16: ...you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be...

Отзывы: