For technical questions, please call 1-888-866-5797.

Item 64017

Sa
F

ety

Opera

ti

O

n

Maintenance

Setup

14�  Do not operate Meter if under the 

influence of alcohol or drugs�  Read 
warning labels on prescriptions to 
determine if your judgment or reflexes 
are impaired while taking drugs� If there 
is any doubt, do not operate the Meter�

15�  People with pacemakers should 

consult their physician(s) before 
use�  Electromagnetic fields in close 
proximity to heart pacemaker could 
cause pacemaker interference 
or pacemaker failure�

16�  Do not test voltage on circuits higher 

than 1000 VDC or 750 VAC�

17�  Do not test current on circuits 

higher than 1000A�

18�  Dress properly�  Protective, 

electrically nonconductive 
clothes and nonskid footwear are 
recommended when working�

19�  Wear ANSI-approved safety 

goggles during use�

20�  Only use accessories intended 

for use with this Meter�

21�  Avoid damaging Meter� Use only 

as specified in this manual�

22�  Prior to testing resistance, diodes, 

or continuity; disconnect all power 
to the circuit and discharge all 
high-voltage capacitors�

23�  Performance of this Meter may vary 

depending on battery condition�

24�  Use the proper settings, terminals, 

techniques, and range for the 
tests performed�  Start with the 
range stated in the instructions�

25�  Do not apply voltage to the Test 

Leads when the Meter is in the 
Ohms testing setting�  Damage 
can occur to the Meter�

26�  Do not switch between testing modes 

with the Meter connected to a circuit�

27�  Do not use the Meter at a setting 

marked as blank on the scale�

28�  Have Meter calibrated by a 

qualified technician every year 
to maintain accurate results�

29�  Do not disassemble charger; 

take it to a qualified technician 
when service or repair is required� 
Incorrect reassembly may result 
in a risk of electric shock or fire�

30�  The warnings, cautions, and 

instructions discussed in this 
instruction manual cannot cover all 
possible conditions and situations 
that may occur� It must be understood 
by the operator that common sense 
and caution are factors which cannot 
be built into this product, but must 
be supplied by the operator�

 SaVe tHeSe inStructiOnS.

Содержание 1000a

Страница 1: ...ence 17i When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All...

Страница 2: ...sed to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will resul...

Страница 3: ...them c The battery is low d Near any explosive gasses or fumes e Any abnormal operation is detected If in doubt about the condition of the Meter have it serviced before use f The battery cover is ope...

Страница 4: ...e diodes or continuity disconnect all power to the circuit and discharge all high voltage capacitors 23 Performance of this Meter may vary depending on battery condition 24 Use the proper settings ter...

Страница 5: ...Hz Inrush Current Accuracy 0A 60A Reference only 600A 1000A 5 0 of rdg 60D Resistance Ranges 600 6k 60k 600k 6M 60M Resistance Accuracy 600 600k 0 8 of rdg 3D 6M 60M 2 0 of rdg 5D Continuity Meter bee...

Страница 6: ...iOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions current clamp rotary Switch Function Button Backlight reading Ho...

Страница 7: ...Power Off autO Auto range mode inr Inrush mode Continuity Diode test reL Relative measurement mode ncV Non contact voltage detection MaX The maximum value is being measured Min The minimum value is b...

Страница 8: ...utton to return to auto range note Manual range cannot be used while measuring frequency Frequency and Duty cycle Measurements 1 While working with voltage or current ranges press the Hz button one ti...

Страница 9: ...isplay To activate data hold 1 Press the B L HOLD button and the reading will be held on the Display The symbol appears 2 Press B L HOLD again to release the hold ncV non contact Voltage 1 Turn Rotary...

Страница 10: ...tions note When using manual range mode always start with the highest range if the amperage is unknown note Center conductor between guides in Clamp jaws as shown ac Dc current Measure AC and DC condu...

Страница 11: ...to OFF and store Meter note If the Display shows OL while in manual range mode the measurement has exceeded the selected range A higher range should be selected ac Dc Voltage Measurement Measure AC co...

Страница 12: ...on the Display 5 When testing is complete turn Rotary Switch to OFF and store Meter note Current test range is 10Hz 1kHz in Voltage Frequency Mode 1 Plug black test lead into cOM Jack Plug red test le...

Страница 13: ...r This is due to the Meter s output test current going through all possible paths between leads note For resistance measurements above 1M allow a few seconds to get a steady reading note When leads ar...

Страница 14: ...s cathode 5 Read measured forward biased voltage drop on the Display note If the test leads are reversed or open OL is displayed 6 When testing is complete turn Rotary Switch to OFF remove Test Leads...

Страница 15: ...tion 4 Other than the batteries there are no replaceable parts on this unit repairs should be done by a qualified technician Battery replacement If the sign appears on the Display the battery should b...

Страница 16: ...you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be...