098-0003 Rev. B 

 
Note: Water with a silt density index (SDI) above 5 SDI will foul the membrane. 

 

Note:

 

For specifications on system components related to electrical  

 

requirements, system pressures and voltage draws, please refer to listed  

 component manuals as listed below. 

 

 

 

 

For 00SRO1095 RO, refer to Manual 98-0150 

 

For 00MW200 Silex Wall Mount Deionizer, refer to Manual 98-0160 
 
For 0185-8000 Healthcare Storage Tank, refer to Manual 098-0001 
 
For 0021003 Loop Endotoxin Filter, refer to Manual 98-0033 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SPD

Страница 1: ...098 0003 Rev B MOBILE SPD FOR STERIS OPERATION MAINTENANCE MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414...

Страница 2: ...098 0003 Rev B...

Страница 3: ...RAM 4 2 0 SYSTEM INSTALLATION 5 2 1 SRO 5 2 2 WALL MOUNT DI 6 2 3 STORAGE TANK 8 2 4 ENDOTOXIN FILTER 9 3 0 SYSTEM START UP 9 3 1 OPERATION 10 4 0 MONITORING 11 5 0 PREVENTATIVE MAINTENANCE SCHEDULE F...

Страница 4: ...cation resin bead then an anion then another cation another anion and so on An exchange takes place of course only when a positive ion contacts a negative exchange site and vice versa With each excha...

Страница 5: ...he Operations Manual before using the system Contact AmeriWater Customer Service with any questions at 1 800 535 5585 Monday through Friday 8 00 a m to 5 00 p m eastern standard time For after hours e...

Страница 6: ...to electrical requirements system pressures and voltage draws please refer to listed component manuals as listed below For 00SRO1095 RO refer to Manual 98 0150 For 00MW200 Silex Wall Mount Deionizer...

Страница 7: ...4 098 0003 Rev B 1 2 SYSTEM FLOW DIAGRAM Figure 1 1...

Страница 8: ...e wall with anchoring bolts 3 SRO is equipped with sediment and chlorine removal 4 Connect the feed water supply to the inlet 1 2 fitting on the SRO prefilter 5 The feed water supply requires a minimu...

Страница 9: ...e of supporting 50 pounds 1 Locate the DI Polisher to the right of the SRO just before the storage tank and within 6 feet from a 120 volt 60 hertz receptacle 2 Assembly should be level when mounted to...

Страница 10: ...1 2 MPT x 3 4 GHT outlet fitting Figure 2 2 FIGURE 2 2 5 Make sure that the deionizing cartridges are installed in the filter housing and that the bowls are hand tightened only 6 Plug transformer into...

Страница 11: ...ct the Wall Mount DI product outlet hose to the storage tank s inlet Figure 2 2 above 3 Connect the tank outlet to the distribution pump Figure 2 3 FIGURE 2 3 4 Run the float switch quick disconnect f...

Страница 12: ...to prevent microbiological growth and freezing Discard all product water for at least two hours of operation before placing the RO in service NOTE As each component is started and flushed of any debri...

Страница 13: ...at the TDS is above the pre determined set point the alarm lamp will light and the HI TDS warning message will show on the display This warning will clear when the TDS drops below the Setpoint The DI...

Страница 14: ...uality management system using continuous reading monitors that measure product water quality total dissolved solids These measurements can provide a measure of equipment performance 3 Cartridge filte...

Страница 15: ...PARAMETERS INITIALS Feed Water Temperature 50 F 80 F Feed Water Pressure 20PSI Pump PSI 100 200PSI Product Flow GPM 0 55 0 76 Reject Flow GPM ADJUSTED EQUAL TO PRODUCT Product Quality TDS 25ppm Total...

Страница 16: ...r 20 6001 must be replaced in the event of listed instances below 1 Red light the red light warns that the water conductivity is above the threshold value of 200 000 ohm For 0185 8000 Storage Tank Ven...

Страница 17: ...rees F Gages are located on face plate of the RO and top of the Pre filter housing Return on the Storage Tank and the inlet and outlet of Endotoxin filter Fig 5 1 Step 4 Membranes Remove membranes fro...

Страница 18: ...15 098 0003 Rev B Figure 5 1...

Страница 19: ...0024 END CAP 2 25 and 40 SS HSG SMALL BLUE O RING RO Membrane 21 0035 O RING FLTR HOUS 10 SLIMLINE BLUE BLK 50I O NO PR Prefilter Vent Filter and DI 21530233 O RING FLTR HSG 10IN BB SQ THD Loop Endoto...

Страница 20: ...ifornia to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may cont...

Отзывы: