2.0     SYSTEM INSTALLATION 
 

CAUTION:

 

Local plumbing and electrical codes must be observed

.   

 

 
 
2.1 

SRO 

 

1. 

The electrical source for the S100 controller must be a single phase, 3-conductor 
receptacle with a ground fault interrupter (GFI) at 120V, 20amp, and 60Hz.  The 
proper polarity and ground integrity must be initially checked and thereafter 
maintained.  Failure to do so may result in electrical shock to the operator.  The SRO 
must only be plugged directly into a GFI receptacle.  It must not be plugged into an 
extension cord or power strip that could cause low amperage. 

 

To avoid electrical shock, always unplug and disconnect the SRO system 
power source before opening the back of the electrical controller. 

 
 
2. 

Mount the SRO (level) on a wall near a drain that can handle the reject water flow. (It 
is recommended to secure the frame to the wall with anchoring bolts.) 
 

3. 

SRO is equipped with sediment and chlorine removal. 
 

4. 

Connect the feed water supply to the inlet 

1/2” fitting on the SRO prefilter. 

 

5. 

The feed water supply requires a minimum dynamic pressure of 20 psi and maximum 
of 50 psi (at the pre filter gauge).  Feed water supply tubing should be large enough to 
provide the required feed flow rate for the SRO. Connect the water supply from your 
isolation valve to the INLET of the pre filter.  

 

6. 

Connect the REJECT WATER to an open drain, maintaining a 2” air gap. 

 

7. 

Connect a product line to the fitting marked PRODUCT WATER. 

 
8. 

Remove and discard the 5 micron sediment filter (part number 20-1051) that has been 
factory installed and Install the supplied 10 micron Carbon Block filter cartridge (part 
number 20-5101). 

 
9. 

Always maintain water flow and pressure to avoid damage to the RO pump.  
   

 

CAUTION:   To ensure proper assembly, all tubing extensions MUST be fully inserted 

into fitting bodies, to the tube stops. 

 

10. 

Plug the power cord into a dedicated 120-volt, 20-amp GFI receptacle. 

 

Содержание SPD

Страница 1: ...098 0003 Rev B MOBILE SPD FOR STERIS OPERATION MAINTENANCE MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414...

Страница 2: ...098 0003 Rev B...

Страница 3: ...RAM 4 2 0 SYSTEM INSTALLATION 5 2 1 SRO 5 2 2 WALL MOUNT DI 6 2 3 STORAGE TANK 8 2 4 ENDOTOXIN FILTER 9 3 0 SYSTEM START UP 9 3 1 OPERATION 10 4 0 MONITORING 11 5 0 PREVENTATIVE MAINTENANCE SCHEDULE F...

Страница 4: ...cation resin bead then an anion then another cation another anion and so on An exchange takes place of course only when a positive ion contacts a negative exchange site and vice versa With each excha...

Страница 5: ...he Operations Manual before using the system Contact AmeriWater Customer Service with any questions at 1 800 535 5585 Monday through Friday 8 00 a m to 5 00 p m eastern standard time For after hours e...

Страница 6: ...to electrical requirements system pressures and voltage draws please refer to listed component manuals as listed below For 00SRO1095 RO refer to Manual 98 0150 For 00MW200 Silex Wall Mount Deionizer...

Страница 7: ...4 098 0003 Rev B 1 2 SYSTEM FLOW DIAGRAM Figure 1 1...

Страница 8: ...e wall with anchoring bolts 3 SRO is equipped with sediment and chlorine removal 4 Connect the feed water supply to the inlet 1 2 fitting on the SRO prefilter 5 The feed water supply requires a minimu...

Страница 9: ...e of supporting 50 pounds 1 Locate the DI Polisher to the right of the SRO just before the storage tank and within 6 feet from a 120 volt 60 hertz receptacle 2 Assembly should be level when mounted to...

Страница 10: ...1 2 MPT x 3 4 GHT outlet fitting Figure 2 2 FIGURE 2 2 5 Make sure that the deionizing cartridges are installed in the filter housing and that the bowls are hand tightened only 6 Plug transformer into...

Страница 11: ...ct the Wall Mount DI product outlet hose to the storage tank s inlet Figure 2 2 above 3 Connect the tank outlet to the distribution pump Figure 2 3 FIGURE 2 3 4 Run the float switch quick disconnect f...

Страница 12: ...to prevent microbiological growth and freezing Discard all product water for at least two hours of operation before placing the RO in service NOTE As each component is started and flushed of any debri...

Страница 13: ...at the TDS is above the pre determined set point the alarm lamp will light and the HI TDS warning message will show on the display This warning will clear when the TDS drops below the Setpoint The DI...

Страница 14: ...uality management system using continuous reading monitors that measure product water quality total dissolved solids These measurements can provide a measure of equipment performance 3 Cartridge filte...

Страница 15: ...PARAMETERS INITIALS Feed Water Temperature 50 F 80 F Feed Water Pressure 20PSI Pump PSI 100 200PSI Product Flow GPM 0 55 0 76 Reject Flow GPM ADJUSTED EQUAL TO PRODUCT Product Quality TDS 25ppm Total...

Страница 16: ...r 20 6001 must be replaced in the event of listed instances below 1 Red light the red light warns that the water conductivity is above the threshold value of 200 000 ohm For 0185 8000 Storage Tank Ven...

Страница 17: ...rees F Gages are located on face plate of the RO and top of the Pre filter housing Return on the Storage Tank and the inlet and outlet of Endotoxin filter Fig 5 1 Step 4 Membranes Remove membranes fro...

Страница 18: ...15 098 0003 Rev B Figure 5 1...

Страница 19: ...0024 END CAP 2 25 and 40 SS HSG SMALL BLUE O RING RO Membrane 21 0035 O RING FLTR HOUS 10 SLIMLINE BLUE BLK 50I O NO PR Prefilter Vent Filter and DI 21530233 O RING FLTR HSG 10IN BB SQ THD Loop Endoto...

Страница 20: ...ifornia to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may cont...

Отзывы: