21
FACTORY AS
SETPOINT
DESCRIPTION
RANGE
SETTING
SHIPPED
Flush Interval
The interval between flush cycles.
0-99
0
24
Only valid with operation hour,
minutes
elapsed time or off flush types.
Flush Mode
Selects if the inlet and RO pump
1-4
0
0
relays operate during flush.
Maximum Hours
If the current operating hours exceed
0-65000
0
0
this limit, the operating hours warning hours
will occur. To disable, set to 0.
Current Hours
Current number of hours of RO
0-65000
0
2
system operation.
hours
Expander Mode
Not Used
-
Temp Offset
Allows adjustment of temperature
+ 5
0
0
reading by +-5 degrees.
Temp UOM
Selects display of temperature in
0-1
0
0
°
F or
°
C
Switch Select
Selects if switch inputs are normally
0-32
0
0
open or normally closed.
TDS/Cond UOM
Selects display of water quality in uS
0-1
0
0
or PPM
NOTE: If this Setpoint is changed,
the unit must be recalibrated.
TDS/Cond Range Selects range of TDS/Conductivity
0-6
1
1
monitor 0-50, 1-100, 2-250, 3-500,
4-1000, 5-2500, 6-5000
NOTE: If this Setpoint is changed,
the unit must be recalibrated.
C2 Range Selects range of TDS/Conductivity
0-6
4
4
monitor 0-50, 1-100, 2-250, 3-500,
4-1000, 5-2500, 6-5000
NOTE: If this Setpoint is changed,
the unit must be recalibrated and
range components may need to be
changed.
FACTORY AS
Содержание 00HRO64800
Страница 6: ...5 SECTION 3 COMPONENTS AND SCHEMATICS 3 1 HRO COMPONENT IDENTIFICATION...
Страница 8: ...7 3 2 HRO FLOW DIAGRAM...
Страница 9: ...8 3 3 HRO ELECTRICAL SCHEMATIC...
Страница 19: ...18 FIGURE 5 2...
Страница 20: ...19 FIGURE 5 3...
Страница 37: ...36 9 2 SPARE PARTS LIST...