AmeriFlow Water Systems Inc. ET6500GRO Скачать руководство пользователя страница 8

7

     07\15 RO Manual

3. 3/8” black Drain Tube from Faucet

 Connect this tube to the black 3/8” drain clamp. 

(See

D in Figure 2 on page 6)

. Tighten firmly so tube will not pull out of drain clamp. 

IMPOR-

TANT:

 Do not leave excessive slack in drain tubing. Shorten tubing so that it flows

directly to the drain with no dips, loops, low spots, or kinks.

4. Post Filter Connection to Faucet

 Depending on the model, connect the 3/8” blue tube

from either the outlet side of the post-filter bowl or the outlet fitting from the 10” inline post-

filter cartridge to the 3/8” Push-In adapter fitting on the RO faucet.

5. RO Tank Connection

 Depending on the model, connect the 3/8” blue tube from either the

tee of the inlet side of the post-filter bowl or the tee of the inlet side of the 10” inline post-

filter cartridge to the Push-In ball valve on top of the RO storage tank.

STEP 7 SYSTEM START-UP PROCEDURES

Turn your sink cold water supply valve to the on position while leaving the Filter Pac/RO mod-

ule and RO tank ball valves in the off position (horizontal, which is perpendicular to the valve). 

Check for leaks and adjust as necessary.

1. Slowly turn Filter Pac/RO module ball valve to the on position (blue valve vertical, which is

in line with the valve). As water enters the filter bowls and makes its way through the filters

to the membrane element you will hear air escaping through the drain. This is normal.

Open RO faucet on the sink until the water starts coming out. (Water flow will only be a

trickle and may take up to 20 minutes before water starts to come out of the faucet spout

on some units). Shut RO faucet off and check for leaks and adjust as necessary.

2. Open the tank ball valve by turning handle a ¼ turn toward the tubing. Let tank fill for 4 to

6 hours (if you are changing filters, your tank may already be full, so you would not need

to wait). Then turn on RO faucet and drain tank completely, (approx. 5 minutes). Shut RO

faucet off, allow tank to refill, and drain again in 4 to 6 hours. The RO system is shipped

with a food grade preservative and must be flushed out prior to use. 

DO NOT DRINK THE

RO WATER UNTIL TANK HAS BEEN DRAINED TWICE.

3. Shut RO faucet off and let system fill again. RO water is now ready for use.

IMPORTANT: Check carefully for small leaks every few hours for the first few days to assure 

there are no leaks. It is wise on any RO system to inspect for leaks since the system sits 

unseen underneath your sink and a small leak may not be detected without close inspection. 

Check for leaks occasionally thereafter and make adjustments as necessary.

STEP 8 REFRIGERATOR ICEMAKER HOOK-UP

1. If there is not an ice-line from the RO to the refrigerator, you may choose to run an ice-line

so that your ice and water dispenser will have filtered water. If the distance from the refrig-

erator to the RO is more than 50’, we recommend 3/8” polypropylene or polyethylene tub-

ing for best results. 

DO NOT USE COPPER.

 (Be sure you have the recommended water

pressure to your icemaker according to the refrigerator manufacturer’s specifications.) 3/8”

tubing, a supplemental storage tank, more RO air pressure, or different usage patterns,

may be required to supply adequate pressure!

2. Connect tube 

(not included)

 to appropriate refrigerator connection and to a plastic “T”

fitting 

(not included)

 spliced into the 3/8” blue tube between the post filter and faucet. It

is recommended to install a ball valve on the tube to the refrigerator for service and start

up purposes. Keep ball valve off until start up procedures are completed and RO tank is

completely full after the second tank draining.

IMPORTANT: Never turn on icemaker before RO tank is full of water to avoid damaging re-

frigerator solenoid. If your refrigerator has a water dispenser in the door, upon initial start-up 

you will need to depress the water supply lever 2 to 3 minutes before the water will dispense.

STEP 9 RECOMMENDED FILTER SERVICE LIFE

The types of filters listed below vary depending on RO system style. The manufacturer 

provides very high capacity carbon filters and replacement intervals are based on our filters. 

Содержание ET6500GRO

Страница 1: ...07 15 RO Manual A Owners Manual FOR REVERSE OSMOSIS SYSTEMS MODEL ET6500GRO P N 10 02 1330GRO Includes Installation and Service Procedures Specifications and Operation Guidelines ...

Страница 2: ...Benefits 2 Specification Limitations 2 Warnings 3 Photo of ROs and Contents List 4 Installation Procedures 4 System Position 4 Faucet Installation 4 Figure 1 Diagram 5 Easy Tap Adapter Installation 5 Drain Saddle Clamp Installation 5 Figure 2 Diagram 6 Storage Tank Preparation 6 Tubing Connections 6 System Start Up Procedures 7 Refrigerator Icemaker Hookup 8 Recommended Filter Service Life 7 Filte...

Страница 3: ... coolers 16 Bottled Water CONTENTS OF PACKAGE 1 Filter Pac RO module 2 Storage Tank 3 Owner s Manual 4 Warranty Registration Card 5 Standard air gap faucet or optional col ored faucet 6 Parts Bag Easy Tap Adapter w washer plastic Drain Clamp black plastic Coupler plastic for use w air gap faucet Faucet Adapter plastic 7 16 fip 3 8 push Tank Ball Valve Mounting Screws 7 Water quality monitor TOOLS ...

Страница 4: ...drain line gets plugged from obstruction in the drain line 9 Water containing iron in excess of 1ppm will require some pretreatment Consult your local water authority 10 This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to as...

Страница 5: ...the Filter Pac RO module and that the mounting screws will not pierce through the wall Hang Filter Pac RO module to assure sufficient space is allowed Remove Filter Pac RO module from the wall for now and continue with install STEP 2 FAUCET INSTALLATION 1 Check for an extra hole in the sink You must drill a 1 hole for the faucet if the sink does not have one Determine Location of Faucet Hole Check...

Страница 6: ...cation of Drain Clamp SINK WITH DISPOSAL Select location to place drain saddle clamp Best choice is the vertical pipe as near the sink as possible making certain that the drain clamp is above the horizontal garbage disposal waste pipe When connecting the black drain tube to drain saddle clamp keep the tube run as straight FIGURE 1 countertop faucet stem B A F slot washer white spacer washer lock w...

Страница 7: ...nd tank air pressure 4 Tank pressure can be increased to improve water flow to the faucet or refrigerator Air pressure can only be tested when tank is completely empty of water Air pressure of 5 PSI minimum 12 PSI maximum is recommended The higher the air pressure the smaller the volume of water the tank will hold Pressure of 10 12 PSI may be necessary to feed a line to the refrigerator Over press...

Страница 8: ...refill and drain again in 4 to 6 hours The RO system is shipped with a food grade preservative and must be flushed out prior to use DO NOT DRINK THE RO WATER UNTIL TANK HAS BEEN DRAINED TWICE 3 Shut RO faucet off and let system fill again RO water is now ready for use IMPORTANT Check carefully for small leaks every few hours for the first few days to assure there are no leaks It is wise on any RO ...

Страница 9: ...pending on influent water quality and hardness See Performance Indicator information listed below Carbon Post filter Carbon MAP Filter These filters need to be changed at least every 12 months to insure quality water Do not wait until taste is a problem Performance indicator The RO system contains a replaceable treatment component criti cal for effective reduction of TDS Total Dissolved Solids The...

Страница 10: ...in off po sition Remove old pre filters and membrane from housings Remove the post filter On the ET5000 a 3 8 union and on the ET6000 a 3 8 reducer union not included will be necessary to reconnect the tubing together without the post filter installed during sanitizing procedures 4 Carefully put 2 capfuls of household bleach into the empty filter bowl canisters Re install filter bowls without filt...

Страница 11: ...1404 1 JG 90 Ball Valve 2 804 11 04 Hex Nipple 1 419 1406 3 8 JG 90 Ball Valve Storage Tank 2 3 805 40 02 Fitting mpt JG Elbow ET6000 1 123 541 Water Conservation Shut Off Valve 1 138 150GRO 50 GPD GRO Membrane 1 128 R O ring Membrane Housing 2 805 40 04 Fitting 1 8 mpt JG Elbow 1 121 1604 1 Check Valve Fitting 1 8 mpt JG Elbow 1 129 260 Flow Restrictor 260 ml 1 110 03181 3 2 Gallon Storage Tank 1...

Страница 12: ...s of water If just air will float to surface and dissipate System is still new This is normal and should clear up in two weeks Noisy drain or faucet Air gap faucet A little noise is common with air gap faucets Check manual to be sure installed in proper location Allow two weeks for air to work out of system Drain tube Check that drain tube from faucet is continuously down hill to drain Loops or di...

Страница 13: ... If damaged replace tube System is con tinually running Shut off valve not working Replace shut off valve Low city supply water pressure Increase water pressure to 40 PSI with a pump Bad check valve Replace check valves Ice being made in refrigerator Nothing you can do ice is made on demand System is new Allow 2 weeks for air to bleed Ice maker not working Ball valve to ice line is off Turn on bal...

Страница 14: ...e product water shall be tested regularly to verify that the system is perform ing properly Testing can be accomplished by contacting the service company that installed your RO system or an authorized dealer If a service company is not available in your area a water sample may be sent to AmeriFlow for a free TDS test of your RO water Additionally a water quality monitor is available for purchase f...

Страница 15: ...We have any parts you need for this unit We are happy to give you advice and instruction relating to the operation of this unit Contact us at AZH2O COM ...