AmeriFlow Water Systems Inc. ET6500GRO Скачать руководство пользователя страница 6

5

     07\15 RO Manual

STEP 3 EASY TAP ADAPTER INSTALLATION

Turn off cold water supply to the sink faucet and relieve pressure by opening the cold water 

faucet. (Repair any existing plumbing sink leaks before continuing). Follow water supply from 

the cold water supply valve, toward the sink faucet, until you reach a coupling nut (may be at 

the base of the faucet). Unscrew the coupling nut. Place rubber washer into the plastic easy 

tap faucet adapter and screw adapter onto location of coupling nut. Hand-tighten, then tighten 

one more complete turn with a wrench. Re-attach the supply line to the adapter with the cou-

pling nut. 

Leave the cold water off.

CAUTION:

1. When tightening easy tap, make sure the tube to which you are attaching the easy tap is

not twisted. Use two wrenches to hold existing tube while tightening the easy tap adapter.

2. Examine existing cone shaped washer on water supply tube, adjust or replace if damaged

or worn 

(not included).

3. If 

self-piercing valve

 is used instead of easy tap, attach to hard copper tubing only. Do not

over tighten screws 

(see instructions on piercing valve package, not included).

NOTE: Push-In style fittings are designed for ease of use. Simply push the tubing in until it seats. Give a tug 

on it to make sure it is secure. Insert red locking clip between fitting and collar. If you need to remove the 

tubing, remove the red locking clip, hold the locking ring collar against the fitting while pulling out the tubing. 

No inserts or nuts are used with the Push-In style fittings.

STEP 4 DRAIN SADDLE CLAMP INSTALLATION

Location of Drain Clamp

SINK WITH DISPOSAL

Select location to place drain saddle clamp. Best choice is the vertical pipe as near the sink as 

possible making certain that the drain clamp is above the horizontal garbage disposal waste 

pipe. When connecting the black drain tube to drain saddle clamp keep the tube run as straight 

FIGURE 1

countertop

faucet stem

B

A

F

slot washer

white spacer

washer
lock washer (optional)

9/16” nut

5/8” nut × 3/8” tube 

adapter

for your type of sink. Place an old towel under 

the sink to catch any metal filings and to make 

clean up easy. After drilling, clean up metal filings 

quickly to avoid staining the porcelain.

2.

Install Air-gap Faucet

 Pre-assemble faucet prior

to installing on the sink. Place the 

white spacer

onto faucet stem flat side toward tubing and open

end upward. Slide spacer up the stem leaving

enough room for the thickness of the sink. Place

the 

washer 

onto the stem and thread on the 

7/16”

nut

 up to the spacer. Attach the plastic 

3/8” faucet

adapter fitting

 to the base of the faucet stem 

(do

NOT over-tighten)

See A in Figure 1 on the right

.

3.

Guide the (2) tubes and the faucet stem

through the hole on the sink until the faucet rests

on top of the sink. Center the faucet over the hole.

Position the faucet so the air-gap hole and the

faucet lever point toward the sink basin (in case

drain tube plugs causing water to spill out of the

air-gap hole). Insert the 

slotted washer

 under the

sink between the 

white spacer

 and the base of

the sink. Tighten the 

7/16” nut

 securing the 

white

spacer

 tight against the sink. 

(see B in Figure)

Faucet may require repositioning before final

tightening. Remove short packing tubing from top

of faucet and insert faucet spout by pushing spout

straight into the hole until it seats.

Содержание ET6500GRO

Страница 1: ...07 15 RO Manual A Owners Manual FOR REVERSE OSMOSIS SYSTEMS MODEL ET6500GRO P N 10 02 1330GRO Includes Installation and Service Procedures Specifications and Operation Guidelines ...

Страница 2: ...Benefits 2 Specification Limitations 2 Warnings 3 Photo of ROs and Contents List 4 Installation Procedures 4 System Position 4 Faucet Installation 4 Figure 1 Diagram 5 Easy Tap Adapter Installation 5 Drain Saddle Clamp Installation 5 Figure 2 Diagram 6 Storage Tank Preparation 6 Tubing Connections 6 System Start Up Procedures 7 Refrigerator Icemaker Hookup 8 Recommended Filter Service Life 7 Filte...

Страница 3: ... coolers 16 Bottled Water CONTENTS OF PACKAGE 1 Filter Pac RO module 2 Storage Tank 3 Owner s Manual 4 Warranty Registration Card 5 Standard air gap faucet or optional col ored faucet 6 Parts Bag Easy Tap Adapter w washer plastic Drain Clamp black plastic Coupler plastic for use w air gap faucet Faucet Adapter plastic 7 16 fip 3 8 push Tank Ball Valve Mounting Screws 7 Water quality monitor TOOLS ...

Страница 4: ...drain line gets plugged from obstruction in the drain line 9 Water containing iron in excess of 1ppm will require some pretreatment Consult your local water authority 10 This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to as...

Страница 5: ...the Filter Pac RO module and that the mounting screws will not pierce through the wall Hang Filter Pac RO module to assure sufficient space is allowed Remove Filter Pac RO module from the wall for now and continue with install STEP 2 FAUCET INSTALLATION 1 Check for an extra hole in the sink You must drill a 1 hole for the faucet if the sink does not have one Determine Location of Faucet Hole Check...

Страница 6: ...cation of Drain Clamp SINK WITH DISPOSAL Select location to place drain saddle clamp Best choice is the vertical pipe as near the sink as possible making certain that the drain clamp is above the horizontal garbage disposal waste pipe When connecting the black drain tube to drain saddle clamp keep the tube run as straight FIGURE 1 countertop faucet stem B A F slot washer white spacer washer lock w...

Страница 7: ...nd tank air pressure 4 Tank pressure can be increased to improve water flow to the faucet or refrigerator Air pressure can only be tested when tank is completely empty of water Air pressure of 5 PSI minimum 12 PSI maximum is recommended The higher the air pressure the smaller the volume of water the tank will hold Pressure of 10 12 PSI may be necessary to feed a line to the refrigerator Over press...

Страница 8: ...refill and drain again in 4 to 6 hours The RO system is shipped with a food grade preservative and must be flushed out prior to use DO NOT DRINK THE RO WATER UNTIL TANK HAS BEEN DRAINED TWICE 3 Shut RO faucet off and let system fill again RO water is now ready for use IMPORTANT Check carefully for small leaks every few hours for the first few days to assure there are no leaks It is wise on any RO ...

Страница 9: ...pending on influent water quality and hardness See Performance Indicator information listed below Carbon Post filter Carbon MAP Filter These filters need to be changed at least every 12 months to insure quality water Do not wait until taste is a problem Performance indicator The RO system contains a replaceable treatment component criti cal for effective reduction of TDS Total Dissolved Solids The...

Страница 10: ...in off po sition Remove old pre filters and membrane from housings Remove the post filter On the ET5000 a 3 8 union and on the ET6000 a 3 8 reducer union not included will be necessary to reconnect the tubing together without the post filter installed during sanitizing procedures 4 Carefully put 2 capfuls of household bleach into the empty filter bowl canisters Re install filter bowls without filt...

Страница 11: ...1404 1 JG 90 Ball Valve 2 804 11 04 Hex Nipple 1 419 1406 3 8 JG 90 Ball Valve Storage Tank 2 3 805 40 02 Fitting mpt JG Elbow ET6000 1 123 541 Water Conservation Shut Off Valve 1 138 150GRO 50 GPD GRO Membrane 1 128 R O ring Membrane Housing 2 805 40 04 Fitting 1 8 mpt JG Elbow 1 121 1604 1 Check Valve Fitting 1 8 mpt JG Elbow 1 129 260 Flow Restrictor 260 ml 1 110 03181 3 2 Gallon Storage Tank 1...

Страница 12: ...s of water If just air will float to surface and dissipate System is still new This is normal and should clear up in two weeks Noisy drain or faucet Air gap faucet A little noise is common with air gap faucets Check manual to be sure installed in proper location Allow two weeks for air to work out of system Drain tube Check that drain tube from faucet is continuously down hill to drain Loops or di...

Страница 13: ... If damaged replace tube System is con tinually running Shut off valve not working Replace shut off valve Low city supply water pressure Increase water pressure to 40 PSI with a pump Bad check valve Replace check valves Ice being made in refrigerator Nothing you can do ice is made on demand System is new Allow 2 weeks for air to bleed Ice maker not working Ball valve to ice line is off Turn on bal...

Страница 14: ...e product water shall be tested regularly to verify that the system is perform ing properly Testing can be accomplished by contacting the service company that installed your RO system or an authorized dealer If a service company is not available in your area a water sample may be sent to AmeriFlow for a free TDS test of your RO water Additionally a water quality monitor is available for purchase f...

Страница 15: ...We have any parts you need for this unit We are happy to give you advice and instruction relating to the operation of this unit Contact us at AZH2O COM ...