39
1
6
7
5
8
19
10
9
15
16
14
13
11
18
4
1. BLOWER
2. TEMPERATURE SWITCH (NOT SHOWN)
3. PRESSURE SWITCH (NOT SHOWN)
4. BAFFLE
5. COLD WATER DIP TUBE
6. HEAT TRAMP (SOME MODELS)
7. ANODE ROD (NOT SHOWN)
8. TEMPERATURE & PRESSURE RELIEF VALVE
9. DRAIN VALVE
10. ELECTRONIC VALVE (PROPANE GAS VALVE
WILL BE MARKED FOR LP GAS ONLY)
11. MANIFOLD
12. ORIFICE (NOT SHOWN)
13. MAIN BURNER
14. HOT SURFACE
15. FV SENSOR
16. VAPOR SENSOR BRACKET
17. HARNESS SENSOR FVR AND TOD
(NOT SHOWN)
18. EXTERIOR DOOR
19. ELECTRICAL SWITCH
ITEM PARTS DESCRIPTION
REPAIR
PARTS
ILLUSTRATION
LEGEND A
Special anode rod
(see page 30)
• Temperature & Pressure ReliefValve is required but
may not be factory installed.
• It is imperative the replacement main burner,
main burner orifice, manifold, hot surface and the
electronic valve be ordered for the proper gas type.
Natural gas electronic valve will be marked with a
3.5” pressure setting. Propane gas electronic valve
will be market “For L.P. Gas Only”.