![American Standard Standard Residential Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/american-standard/standard-residential/standard-residential_operating-installation-and-service-manual_2929935025.webp)
22
SOLAR INSTALLATION
When this appliance is used AS A SOLAR STORAGE HEATER OR AS A BACK UP FOR THE SOLAR SYSTEM, the
following warning applies.
Water supply to this heater must not
exceed 180ºF. Water temperature in
excess of 180ºF will cause the high
limit control to function or open
and shut off gas supply. The high
limit control is a single use type that
will require the replacement of the
thermostat before the burner can
operate. If the water supply from
the solar system is above 120ºF, a
tempering valve or temperature
limiting valves must be installed in the
water supply line to limit the supply
temperature to 120ºF.
Insulation blanket kits which area available for external applications to water
heaters are not recommended. However, some governing bodies require their use
in new construction of additions, regardles of how efficient the water heater may
be.
If an insulation blanket is applied to this heater CAUTION must be exercised not
to restrict the proper function of the heater. The manufacturer of this heater will
not be liable for incidents arising or resulting, from the use of external insulation
blankets. The manufacturer will not be liable for corrosion of the parts which may
have resulted from the use of such insulation blankets.
The space between the base and the floor on a gas water heater is necessary for
proper air flow. This space must be maintained unobstructed. As time passes, the
blanket may sag causing an obstruction of this air passage, resulting in an unsafe
operating condition.
Do not apply insulation to the top of a gas water heater, This will affect the
operation of the dradthood, resulting in an unsafe operating condition.
Do not cover any acces panels leading to burner compartments, thermostat(s)
control, doors, or temperature & pressure relief valve on the water heater.
Do not cover any labels or instruction material applied to this water heaterm these
safety labels and instruction materials must remain on the water heater and be
visible for reference by the user. Do not attempt to remove these labels as they are
a permanent part of this water heater as required by Certification Agencies and/or
the Federal Government.
WARNINGS
CAUTION
INSULATION BLANKET