background image

M968845 Rev. 1.2

SpeedConnect™ Drain

Troubleshooting Guide

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled

as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

CABLE ADJUSTMENT PROCEDURE

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:
     •

 Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.

 

                                                                          

Fig.

 

B.

REMOVE
CAM

Fig.

 

E.

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. 

Fig.

 

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. 

Fig.

 

B, C.

 

Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig.

 

C.

Re-attach the Cable to the Drain Body Connection 

(2)

 by threading the Cable Connector 

(1)

 clockwise onto the

Drain Body Connection 

(2)

 and hand-tighten. 

Fig.

 

A.

STOPPER REMOVAL PROCEDURE

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE
CAM CAP

Fig.

 

C.

STOPPER

Fig.

 

F.

5

Fig.

 

A.

DOWN

1

Содержание SPEED CONNECT 4508.4

Страница 1: ...ough valve mounting holes Threads of VALVE BODY 3 3a should extent at least 5 16 of a inch above mounting surface top Fig A Thread DECK ADAPTER 4 onto VALVE BODIES 3 3a until snug against internal sto...

Страница 2: ...USTRATION SHOWN LESS VALVES SLOTTED MOUNTING NUT POP UP ROD ASSEMBLY 2 TIGHTEN LOCKNUT 1 Fig A Fig B REMOVE FLANGE Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain bo...

Страница 3: ...hten Fig B Your new POP UP DRAIN installation is now complete Fig C Note Tailpeice on pop up drain is 1 1 4 O D Fig C Fig B ATTACH CABLE CONNECTOR 8 Operate LIFT KNOB 1 to verify that STOPPER 2 opens...

Страница 4: ...APTER 1 Find correct position of LEVER HANDLE ASSEMBLY 4 by adjusting male teeth on ADAPTER 1 to female teeth in HANDLE 4 Thread LEVER HANDLE ASSEMBLY 4 onto DECK ADAPTER 5 until snug against mounting...

Страница 5: ...low CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOP...

Страница 6: ...at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plas...

Страница 7: ...FOR HELP For toll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a m to 8 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST...

Отзывы: