M968845 Rev. 1.2
INSTALL HANDLES
CHECK DRAIN CONNECTIONS
12
11
13
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Operate both HANDLES
(1)
to flush water
lines thoroughly.
Rotate TRANSFER VALVE
(5)
from rim wash to
spray several times to check operation.
Pull up POP-UP KNOB
(3)
and fill Bidet with water. Check
that DRAIN STOPPER
(4)
makes a good seal and retains
water in Bidet. If STOPPER
(4)
does not seal properly,
please refer to “Troubleshooting Guide” in these instructions.
Push POP-UP KNOB
(3)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
1
1
4
SPRAY
OUTLINE OF BIDET
2
2
4
1
2
4
5
3
TOP
Figure "A"
SPLINE END DOWN
Push ADAPTER
(1)
on VALVE STEM
(2)
, so that the hole of the
ADAPTER
(1)
without a spline is facing up. See figure "A". Tighten
STEM SCREW (3) to secure ADAPTER
(1)
.
Find correct position of LEVER HANDLE ASSEMBLY
(4)
by adjusting
male teeth on ADAPTER
(1)
to female teeth in HANDLE
(4)
.
Thread LEVER HANDLE ASSEMBLY
(4)
onto DECK ADAPTER
(5)
until snug against mounting surface
.
THREAD ON
TO DECK
ADAPTER
14
15
SERVICE
2
90˚
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position. Unthread HANDLE
BASE
(1)
from DECK ADAPTER
(2)
.
Pull HANDLE ASSEMBLY off VALVE STEM
(3)
.
Remove SPRING CLIP
(4)
. Lift STOP WASHER
(5)
,
turn 90˚ and replace. Replace SPRING CLIP
(4)
.
Find correct position of HANDLE ASSEMBLY by adjusting
male teeth on VALVE STEM
(3)
to female teeth in HANDLE.
Thread HANDLE ASSEMBLY onto DECK ADAPTER
(2)
until snug against mounting surface.
If spout drips, operate handles several times from
OFF to ON position. Do not force - handles turn
only 90˚ .
1
4
3
5
UNTHREAD
HANDLE
ASSEMBLY
3
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER.DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
CARE INSTRUCTIONS: