M968567 Rev.1.2

8

IS STOP VALVE OPEN?

LOOK FOR REPEATED

DOUBLE FLASH ON SENSOR

YES

INSTALL NEW BATTERY

TRY MANUAL VALVE BUTTON;

WILL THE UNIT FLUSH?

NO

REPLACE PISTON KIT

INSTALL NEW BATTERY

SEE STEP 10, page 6 in manual

NO

REPLACE SENSOR

NO

YES 

NO 

NO 

YES 

YES 

 

OPEN VALVE

UNIT WILL ONLY FLUSH MANUALLY

LOOK FOR REPEATED

DOUBLE FLASH ON SENSOR

RETRY AUTOMATIC FLUSH.

DOES THE UNIT FLUSH?

RETRY AUTOMATIC FLUSH.

TEST SENSOR. DISCONNECT

GRAY FLAT WIRE FROM BATTERY

COVER AND RE-CONNECT. SENSOR

SHOULD FLASH FOR 5 SECONDS.

DOES IT FLASH?

TEST SENSOR. DISCONNECT

GRAY FLAT WIRE FROM BATTERY

COVER AND RE-CONNECT. SENSOR

SHOULD FLASH FOR 5 SECONDS.

DOES IT FLASH?

CLOSE STOP VALVE,

REPLACE SOLENOID KIT.

RE-ASSEMBLE & INSTALL UNIT.

OPEN STOP VALVE.

BATTERY LOW;

REPLACE BATTERY

SEE STEP 10, page 6 in manual

NO 

NO 

YES 

DOES THE SENSOR FLASH

FOR THE FIRST 5 SECONDS?

NO

REPLACE SOLENOID KIT

RETRY AUTOMATIC FLUSH;

WAS IT SUCCESSFUL?

YES

1. COVER SENSOR FOR 10 SECONDS

2. UNCOVER SENSOR FOR 10 SECONDS.

REPLACE BATTERY

SEE STEP 10, page 6 in manual

MANUAL VALVE

OBSTRUCTED.

CLOSE STOP VALVE

AND SERVICE

RETRY AUTO FLUSH

NO

UNIT IS CONTINUOUSLY FLUSHING

PUSH MANUAL FLUSH

BUTTON; DOES IT RETURN?

LOOK FOR REPEATED

DOUBLE FLASH ON SENSOR

NO 

NO 

YES 

NO

1. COVER SENSOR FOR 10 SECONDS

2. UNCOVER SENSOR FOR 10 SECONDS.

   DOES THE UNIT STOP FLUSHING?

YES

INSTALL NEW BATTERY

SEE STEP 10, page 6 in manual

YES

1. CLOSE STOP VALVE,

2. REPLACE SOLENOID KIT.

3. RE-ASSEMBLE AND INSTALL UNIT.

4. OPEN STOP VALVE.

REPLACE SENSOR

NO

TROUBLESHOOTING FLOW CHARTS

UNIT DOES NOT FLUSH AT ALL

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

W

eekdays 8:00 a.m. to 6:00 p.m. EST

IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)

W

eekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of AS America, Inc.

IN MEXICO  01-800-839-12-00

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Содержание Selectronic Proximity Urinal Flush Valve 6063.051

Страница 1: ...lve prevents clogging and reduces maintenance ONE SENSOR FITS ALL Only 1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote c...

Страница 2: ...RODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE CARE INSTRUCTIONS I n s t a l l a t i o n I n s t r u c t i o n s I n s t a l l a t i o n I n s t r u c t i o n...

Страница 3: ...ents that are subject to normal wear These components should be checked on a regular basis and replaced as needed to maintain the valve s performance IMPORTANT All plumbing must be installed in accord...

Страница 4: ...plied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement ta...

Страница 5: ...Fig 6 4 1 4 Fig 7a Fig 7c Fig 7d Fig 7 3 The UNIT is shipped with the inlet flange on the right side If needed the orientation can be reversed by following the steps below 1 Loosen SET SCREW 1 with 2...

Страница 6: ...imately 3 seconds 4 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace COVER...

Страница 7: ...or order the complete flush valve assembly from American Standard HOW TO RETROFIT OUR VALVE Fig 10 8 Replaces Industry Standard Manual and Electronic Valves CLEAN CONNECTIONS 2 Fig 10 Fig 10a Fig 10b...

Страница 8: ...ecure the CAP 3 at this time Note You have 5 seconds after connecting cable to enter program code 5 While the SENSOR CONTROL LED 6 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the...

Страница 9: ...FIRST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 10 page 6 in manual MANUAL VA...

Страница 10: ...JUSTABLE TAILPIECE M952261 0020A 3 4 INLET PIPE ASSEMBLY M952263 0020A 3 4 VACUUM BREAKER ASSEMBLY M952262 0020A 3 4 SPUD ASSEMBLY SELECTRONIC PROXIMITY URINAL FLUSH VALVE 0 5 1 0 GPF A955058 0020A 3...

Отзывы: