1

1

2

3

4

5

1

4

2

3

Fig. 4

Fig. 5

1.

 Measure from finished wall to first thread of Adapter 

or threaded supply pipe (dimension “X”). Cut COVER 
TUBE 

(1)

 to length (X). Apply Teflon Tape to the 

threaded end of the Adapter or supply pipe. Fig. 4a. 

2.

 Push the COVER TUBE 

(1)

 into the WALL 

ESCUTCHEON 

(2)

. Slide both onto the SUPPLY PIPE 

(3)

. Fig. 4b.

3.

 Push the COVER TUBE 

(1)

 in to expose the threads 

of the supply pipe. Fig. 4c. With a wrench thread the 
SUPPLY STOP 

(4)

 onto the SUPPLY PIPE 

(3)

. Align 

and tighten. Fig. 4c.

4. 

Pull COVER TUBE 

(1)

 against SUPPLY STOP 

(4) 

and push WALL ESCUTCHEON 

(2)

 against finished 

wall. 

 

  

3

    INSTALL COVER TUBE, WALL
ESCUTCHEON and SUPPLY STOP;
Fig. 4

2

TEFLON TAPE

FINISHED WALL

3/4" TOP SPUD

    INSTALL SWEAT SOLDER
ADAPTER; Fig. 3

CAUTION

Turn  water supplies off
before beginning

Note: 

 

Install Optional Sweat Solder Adapter 

(Supplied) for copper pipe supply line.

 

Fig. 3.

1.

 Measure the distance (A) from the finished wall to the 

center of the inlet spud on the fixture.

2.

 Cut the supply pipe 1-1/4" (A-B=C) shorter then the 

measurement taken in Step 1. File any rough edges off 
the end of the supply pipe.

3.

 Clean the end of the supply pipe. Push the threaded 

Adapter on until it is seated against the internal stop. 
Sweat the Adapter to the pipe.

1

CENTER LINE OF
FIXTURE SPUD

FINISHED WALL

FILE EDGES

SOLDER
ADAPTER

Fig.3 

Fig.3a 

ADAPTER

32mm
(1-1/4)

A

(A-B)=

B

C

X

X

CLEAN

1. 

Place the SPUD FLANGE 

(1)

 over the spud on the 

Fixture.

2.

 Thread SPUD COUPLING NUT 

(2)

 onto Spud. 

Make sure SEAL WASHER 

(3)

 and FRICTION 

WASHER 

(4)

 are installed. Do not tighten fully.

3.

 Insert the DOWN TUBE 

(5)

 into the SPUD 

COUPLING NUT 

(2)

 and push it down.

Note:

 

If cutting Down Tube (5) to size, note that 

Critical Line (C/L) on Vacuum Breaker must 
typically be 6

"

 (152mm) above fixture. Consult 

Code for details.

 

    INSTALL DOWN TUBE AND
VACUUM BREAKER; Fig. 5

3

Fig. 4a

Fig. 4b

Fig. 4c

2

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

M968567 Rev.1.2

Содержание Selectronic Proximity Urinal Flush Valve 6063.051

Страница 1: ...lve prevents clogging and reduces maintenance ONE SENSOR FITS ALL Only 1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote c...

Страница 2: ...RODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE CARE INSTRUCTIONS I n s t a l l a t i o n I n s t r u c t i o n s I n s t a l l a t i o n I n s t r u c t i o n...

Страница 3: ...ents that are subject to normal wear These components should be checked on a regular basis and replaced as needed to maintain the valve s performance IMPORTANT All plumbing must be installed in accord...

Страница 4: ...plied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement ta...

Страница 5: ...Fig 6 4 1 4 Fig 7a Fig 7c Fig 7d Fig 7 3 The UNIT is shipped with the inlet flange on the right side If needed the orientation can be reversed by following the steps below 1 Loosen SET SCREW 1 with 2...

Страница 6: ...imately 3 seconds 4 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace COVER...

Страница 7: ...or order the complete flush valve assembly from American Standard HOW TO RETROFIT OUR VALVE Fig 10 8 Replaces Industry Standard Manual and Electronic Valves CLEAN CONNECTIONS 2 Fig 10 Fig 10a Fig 10b...

Страница 8: ...ecure the CAP 3 at this time Note You have 5 seconds after connecting cable to enter program code 5 While the SENSOR CONTROL LED 6 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the...

Страница 9: ...FIRST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 10 page 6 in manual MANUAL VA...

Страница 10: ...JUSTABLE TAILPIECE M952261 0020A 3 4 INLET PIPE ASSEMBLY M952263 0020A 3 4 VACUUM BREAKER ASSEMBLY M952262 0020A 3 4 SPUD ASSEMBLY SELECTRONIC PROXIMITY URINAL FLUSH VALVE 0 5 1 0 GPF A955058 0020A 3...

Отзывы: