background image

5

   M965640 Rev. 1.4 (11/17)

4

     

INSTALL VACUUM BREAKER AND 

FLUSH CONNECTIONS; Fig. 6

1.  Place the SPUD FLANGE (1) over the spud on the Fixture. Fig. 6.

2.  Place FRICTION WASHER (3) and SEAL WASHER (4) inside 

SPUD COUPLING NUT 

(2) and thread onto Spud. Do not tighten 

fully. 

Fig. 6.

3.  Remove the ELBOW COUPLING NUTS (6, 6a) from the CHROME 

ELBOW 

(5). Make sure you have a TAPERED RUBBER WASHER  

(7), PLASTIC SUPPORT (8) and SQUARE SEAL WASHER (9).  

Fig. 6a.

4.  Install the SQUARE SEAL WASHER (9) onto the PLASTIC  

SUPPORT 

(8) if not already installed. Insert the PLASTIC  

SUPPORT 

(8) into the VERTICAL OUTLET PIPE (10).  Slide the  

ELBOW COUPLING NUT 

(6) onto the VERTICAL OUTLET PIPE 

(10). Connect the ELBOW COUPLING NUT (6) to the CHROME 

ELBOW 

(5) and tighten fully.

5.  Insert the VERTICAL OUTLET PIPE (10) with assembled CHROME 

ELBOW 

(5) into the SPUD COUPLING NUT (2) and push it down. 

Do not tighten fully. 

Fig. 6a.

Note: Cutting the VERTICAL OUTLET PIPE (10) may be necessary 

for the CHROME ELBOW (5) center line to line up with opening in 

the wall.

6.  Measure and cut the HORIZONTAL OUTLET PIPE (11) to length 

required. 

Fig. 6b.

Important: Make sure that there is a minimum of 1-1/4for  

engagement with elbow when making your measurement.

7.  Remove the ELBOW COUPLING NUT (14) from BRASS ELBOW 

(12) and slide it onto the HORIZONTAL OUTLET PIPE (11). Install 

the SQUARE SEAL WASHER 

(13) onto the PLASTIC SUPPORT 

(15) if not already installed. Insert the PLASTIC SUPPORT (15) into 

the HORIZONTAL OUTLET PIPE 

(11). Connect the ELBOW  

COUPLING NUT 

(14) to the BRASS ELBOW (12) and tighten fully.   

Fig. 6b.

8.  From behind the wall, insert the assembled BRASS ELBOW and 

HORIZONTAL OUTLET PIPE 

(12, 11) through the hole in the wall. 

Install  WALL ESCUTCHEON 

(16) onto the HORIZONTAL OUTLET 

PIPE 

(11). Slide the ELBOW COUPLING NUT (6a) and TAPERED 

RUBBER WASHER 

(7) onto the HORIZONTAL OUTLET PIPE (11)

Push the HORIZONTAL OUTLET PIPE 

(11) into the CHROME  

ELBOW 

(5). Tighten ELBOW COUPLING NUT (6a) but not fully.  

Fig. 6b

9.  For back spud installations: Follow steps #1 and #2 to install the 

spud coupling kit. Push the HORIZONTAL OUTLET PIPE 

(11) into 

the spud connection on the back of the fixture. Do not tighten fully. 
If spud coupling kit is not required, install HORIZONTAL OUTLET 
PIPE 

(11) into back spud on fixture and hand tighten. Fig. 6b.

10.  All installations: If required, cut scored VACUUM BREAKER PIPE 

(17), leave a minimum of 1-1/4" (32mm) of pipe to ensure  

engagement with compression coupling. Assemble the ELBOW 
COUPLING NUT 

(14a) and TAPERED RUBBER WASHER (19) 

onto the VACUUM BREAKER PIPE 

(17). Install VACUUM  

BREAKER PIPE 

(17) into BRASS ELBOW (12) and hand tighten 

COUPLING NUT 

(14a)Fig. 6c.

Note: If cutting VACUUM BREAKER PIPE (17) to size, note that  

Critical Line (C/L) on Vacuum Breaker must typically be 6" 

(152mm) above fixture. Consult Code for details. 

Fig. 6

Fig. 6a

Fig. 6b

Fig. 6c

1

2
3

4

1-1/2" TOP SPUD

9

6a

8

7

5

6

10

FLANGE END UP

2

TAPERED SIDE 

14

16

12

11

15

5

7

6a

13

FLANGE END 

11

14a

19

19

17

TOP SPUD

INSTALLATION

BACK SPUD

INSTALLATION

BACK SPUD

INSTALLATION

TOP SPUD

INSTALLATION

TAPERED

SIDE 

12

TAPERED SIDE UP 

TAPERED

SIDE UP 

Содержание SELECTRONIC 606B2 Series

Страница 1: ...ail us at CRTTEAM americanstandard com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC CONCEALED TOILET FLUSH VALVE 1 1 1 28 1 6 GPF MODEL NUMBERS 606B2XX CAUTION Use only American Standard supplied transformers and cable sets Using non AS supplied cables or cutting splicing or modifying a...

Страница 2: ...MPLETE POWER KITS SOLD SEPARATELY T O P 2 7 606X 2X1 606X 2X2 VACUUM BREAKER FLUSH CONNECTIONS 606X 2X3 I n s t a l l a t i o n I n s t ru c t i o n s Certified to comply with ASME A112 19 2 2016 AS America Inc SELECTRONIC CONCEALED TOILET FLUSH VALVE 1 28 1 6 GPF Concealed Back Spud Exposed Back Spud Top Spud NOTE TO INSTALLER Please give this manual to the customer after installation NOTE TO INS...

Страница 3: ...TO INSTALLATION Note Prior to installing the Selectronic Flush Valve the following items must be installed 1 Toilet 2 Drain line 3 Water supply line IMPORTANT All plumbing and electrical wiring should be installed in accordance with applicable codes and regulations The use of water hammer arrestors is strongly recommended for commercial applications All piping behind the walls should be properly s...

Страница 4: ... the supply pipe Push the threaded SWEAT ADAPTER 1 until it is seated against the internal stop Sweat the ADAPTER 1 to the pipe 2 Install the STOP VALVE 2 to the water supply line with the outlet positioned as required Behind the Wall 3 Support piping as required 3 FLUSH OUT SUPPLY LINES Fig 5 1 Open STOP VALVE 1 2 Turn on water supply line to flush line of any debris or sediment 3 Close STOP VALV...

Страница 5: ...IZONTAL OUTLET PIPE 11 Connect the ELBOW COUPLING NUT 14 to the BRASS ELBOW 12 and tighten fully Fig 6b 8 From behind the wall insert the assembled BRASS ELBOW and HORIZONTAL OUTLET PIPE 12 11 through the hole in the wall Install WALL ESCUTCHEON 16 onto the HORIZONTAL OUTLET PIPE 11 Slide the ELBOW COUPLING NUT 6a and TAPERED RUBBER WASHER 7 onto the HORIZONTAL OUTLET PIPE 11 Push the HORIZONTAL O...

Страница 6: ...AKERTUBE Fig 8 1 Align the FLUSH VALVE BODY 2 directly above the VACUUM BREAKER TUBE 7 and VACUUM BREAKER COUPLING NUT 6 Make sure that GASKET 10 is installed Note There is a 13mm 6mm 1 2 1 4 tolerance for the 121mm 4 3 4 dimension 2 Pull the VACUUM BREAKER TUBE 7 up to meet the threaded FLUSH VALVE 2 and hand tighten the COUPLING NUT 6 Align all components of the flush valve assembly 3 Lightly ti...

Страница 7: ...o the SOLENOID CABLE 3 Fig 10 3 Insert BATTERY 11 to available SENSOR CABLE 5 and install the CONNECTOR LOCKING DEVICE 7 Place BATTERY 11 to electrical box Fig 10 8 AC VERSION PK00 PAC Power Kit Fig 9 10a 1 Attach the SAFETY CHAIN 1 from the COVER PLATE 2 to the MOUNTING POST 3 as shown Fig 9 2 Connect one end of the 27 EXTENSION CABLE 4 to SENSOR CABLE 5 Connect the other end of the 27 EXTENSION ...

Страница 8: ...ENSION CABLE 2 and connect one end to the available sensor cable the other end to one of the two terminals at the one end of the Y ADAPTER 3 3 Take the 10 EXTENSION 4 and connect one end to the single terminal of Y ADAPTER 3 and the other end to available terminal of the previous unit s Y ADAPTER 3a 4 Repeat process for each subsequent unit 5 Place Y ADAPTERS 3 into respective electrical box 6 Plu...

Страница 9: ... into the two holes located at the bottom of the COVER PLATE 2 Push the WIRE KEY 5 up until it releases the bottom clips Pull the bottom edge away and lift the COVER PLATE 2 off 11 CONNECT OVERRIDE HOSES AC DC POWER Fig 13 1 Push the BLACK HOSE 1 into the BOTTOM HOSE CONNECTOR 2 on flush valve body and push the other end into the back of the MANUAL OVERRIDE VALVE 3 2 Push the BLUE HOSE 4 into the ...

Страница 10: ...allation is complete peel off the PROTECTIVE FILM 1 from the sensor Standing to one side block the sensor with your hand for 10 seconds Remove your hand and listen for audible click from within the valve 2 Turn on STOP VALVE 2 1 4 turn to 1 2 turn CCW and test for leaks Note Unit may flush for approximately 5 to 10 seconds when water is first turned on If flow persists turn water off and repeat st...

Страница 11: ...5 When the LED 5 stops blinking and stays ON move your hand to the desired position from sensor and hold in place until the LED 5 begins to blink again Fig 17 Note Detection Zone is 400mm 800mm Factory Setting 400mm 6 Once the SENSOR CONTROL LED 5 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set 7 Replace and secure COVER PLATE 1 ...

Страница 12: ... RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP PUSH MANUAL OVERRIDE BUTTON DOES IT RETURN TO ITS ORIGINAL POSITION FREELY RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS REPLACE PISTON SOLENOID ASSEMBLY REPEATED DOUBLE FLASH ON SENSOR R...

Отзывы: