11
M965640 Rev. 1.4 (11/17)
C
SET DETECTION RANGE
(if required); Fig. 16 & 17
Note: The detection distance is preset and ideal for most
installations. Should an adjustment be required, follow the
steps below.
1. Remove COVER PLATE (1). See Step 10 for front panel
removal instructions.
2. Disconnect SENSOR CABLE (2) from BATTERY HOLDER
(3) or from POWER SUPPLY 27" EXTENSION CABLE (4).
Fig. 16.
3. Keeping hands away from the front of the sensor, reconnect
the SENSOR CABLE
(2). Do not secure the COVER PLATE
(1) at this time. Fig. 16.
Note: You have 5 seconds to begin entering the program
code after power connection is made.
4. While the SENSOR CONTROL LED (5) is blinking slowly,
place your hand 1 to 2". (30-50mm.) in front of the sensor.
Fig. 17.
5. When the LED (5) stops blinking and stays “ON”, move your
hand to the desired position from sensor and hold in place
until the LED
(5) begins to blink again. Fig. 17.
Note: Detection Zone is 400mm - 800mm.
(Factory Setting: 400mm)
6. Once the SENSOR CONTROL LED (5) begins to blink
again, remove your hand from the detection zone. When
the flashing stops, the detection distance is set.
7. Replace and secure COVER PLATE (1).
8. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
Note: Stand outside of sensor detection area.
B) Remove hand from detection area; unit will flush
in approximately 3 seconds.
Fig. 16
2
1
3
4
T O P
CARE INSTRUCTIONS:
DO:
CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT:
DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH
WITH A COARSE SURFACE.
1
1
Fig. 17
1" - 2" (30mm - 50mm)
BLINKING LED
5
BLINKING LED
DETECTION ZONE
400mm - 800mm
(Factory Setting: 400mm)