background image

3

240mm MAX.

(9-1/2) MAX.

-C-L-

-C-L-

51mm

(2)

70mm

(2-3/4) DIA.

25mm (1) MAX.

160mm

(6-1/4)

OVERRIDE

BUTTON

160mm

(6-1/4)

127mm X 127mm

(5X5 CUTOUT

FOR BOX)

128mm MAX.

(5) MAX.

400mm MAX.

(15-3/4) MAX.

FOR LOCATION OF INLET SUPPLY ON BACK INLET

FIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,

REFER TO FIXTURE INSTRUCTION SHEET.

FINISHED

WALL

CONCEALED BACK

SPUD TOILET

EXPOSED BACK

SPUD TOILET

TOP SPUD

TOILET

TOP OF

FIXTURE

FINISHED

FLOOR

FINISHED

FLOOR

FINISHED

FLOOR

TOP OF

FIXTURE

SENSOR

SUPPLY

(1) NPT

108mm-134mm

(4-1/4 TO 5-1/4)

*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6

" (152mm) min.

above fixture. Consult Codes for details.

51mm

(2)

51mm

(2)

WALL THICKNESS

15˚

TOP OF

FIXTURE

450mm MAX.
(17-3/4) MAX.

DETECTION ZONE

400mm-800mm

(Factory Setting: 400mm)

152mm MIN.

(6) MIN.

*-C-L-

152mm MIN.

(6) MIN.

*-C-L-

360mm MAX.

(14-3/16) MAX.

Fig. 1

  

Roughing-in  

Dimensions

RECOMMENDED TOOLS; Fig. 2.

   1. Teflon Tape

  2. Flat Blade Screwdriver

  3. Adjustable Wrench

  4. Tape Measure

  5. Hacksaw

  6. Tubing Cutter

   7. File

    8. For Sweat Connection; Solder and Torch

    9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench

GENERAL DESCRIPTION:

SELECTRONIC

®

 PROXIMITY TOILET  

FLUSH VALVE
Concealed Flushometer for 1-1/2
"  

Top Spud Fixtures

PRIOR TO INSTALLATION

Note:  Prior to installing the Selectronic™Flush 

Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line

IMPORTANT:

•  

All plumbing and electrical wiring should be  

installed in accordance with applicable codes  

and regulations.

•  The use of water hammer arrestors is strongly     

recommended for commercial applications. All piping

  behind the walls should be properly secured and

  fastened.
•  Water supply lines must be sized to provide an

  adequate volume of water for each fixture.

•  Flush all water lines prior to operation 

(See Step 3).  

Dirt and debris can cause flush valve to run continuously.

• 

With the exception of Stop Valve Inlet, DO NOT    

  use pipe sealant or plumbing grease on any 

  valve component or coupling!

• Protect the chrome or special finish on the Flushometer.

  DO NOT USE toothed tools on finished surfaces to install  

  or service these valves. Also see “Care and Cleaning” 

  section of this manual.

• This product contains mechanical and/or electrical 

  components that are subject to normal wear. These 

  components should be checked on a regular basis and 

  replaced as needed to maintain the valve’s performance. 

Fig. 2

1

2

3

4

5

6

7

9

10

8

10'

   M965640 Rev. 1.4 (11/17)

CAUTION:  Use only American Standard  

supplied transformers and cable sets.  

Using non-AS supplied cables, or cutting,  

splicing or modifying any components will  

void the warranty.

Содержание SELECTRONIC 606B2 Series

Страница 1: ...ail us at CRTTEAM americanstandard com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC CONCEALED TOILET FLUSH VALVE 1 1 1 28 1 6 GPF MODEL NUMBERS 606B2XX CAUTION Use only American Standard supplied transformers and cable sets Using non AS supplied cables or cutting splicing or modifying a...

Страница 2: ...MPLETE POWER KITS SOLD SEPARATELY T O P 2 7 606X 2X1 606X 2X2 VACUUM BREAKER FLUSH CONNECTIONS 606X 2X3 I n s t a l l a t i o n I n s t ru c t i o n s Certified to comply with ASME A112 19 2 2016 AS America Inc SELECTRONIC CONCEALED TOILET FLUSH VALVE 1 28 1 6 GPF Concealed Back Spud Exposed Back Spud Top Spud NOTE TO INSTALLER Please give this manual to the customer after installation NOTE TO INS...

Страница 3: ...TO INSTALLATION Note Prior to installing the Selectronic Flush Valve the following items must be installed 1 Toilet 2 Drain line 3 Water supply line IMPORTANT All plumbing and electrical wiring should be installed in accordance with applicable codes and regulations The use of water hammer arrestors is strongly recommended for commercial applications All piping behind the walls should be properly s...

Страница 4: ... the supply pipe Push the threaded SWEAT ADAPTER 1 until it is seated against the internal stop Sweat the ADAPTER 1 to the pipe 2 Install the STOP VALVE 2 to the water supply line with the outlet positioned as required Behind the Wall 3 Support piping as required 3 FLUSH OUT SUPPLY LINES Fig 5 1 Open STOP VALVE 1 2 Turn on water supply line to flush line of any debris or sediment 3 Close STOP VALV...

Страница 5: ...IZONTAL OUTLET PIPE 11 Connect the ELBOW COUPLING NUT 14 to the BRASS ELBOW 12 and tighten fully Fig 6b 8 From behind the wall insert the assembled BRASS ELBOW and HORIZONTAL OUTLET PIPE 12 11 through the hole in the wall Install WALL ESCUTCHEON 16 onto the HORIZONTAL OUTLET PIPE 11 Slide the ELBOW COUPLING NUT 6a and TAPERED RUBBER WASHER 7 onto the HORIZONTAL OUTLET PIPE 11 Push the HORIZONTAL O...

Страница 6: ...AKERTUBE Fig 8 1 Align the FLUSH VALVE BODY 2 directly above the VACUUM BREAKER TUBE 7 and VACUUM BREAKER COUPLING NUT 6 Make sure that GASKET 10 is installed Note There is a 13mm 6mm 1 2 1 4 tolerance for the 121mm 4 3 4 dimension 2 Pull the VACUUM BREAKER TUBE 7 up to meet the threaded FLUSH VALVE 2 and hand tighten the COUPLING NUT 6 Align all components of the flush valve assembly 3 Lightly ti...

Страница 7: ...o the SOLENOID CABLE 3 Fig 10 3 Insert BATTERY 11 to available SENSOR CABLE 5 and install the CONNECTOR LOCKING DEVICE 7 Place BATTERY 11 to electrical box Fig 10 8 AC VERSION PK00 PAC Power Kit Fig 9 10a 1 Attach the SAFETY CHAIN 1 from the COVER PLATE 2 to the MOUNTING POST 3 as shown Fig 9 2 Connect one end of the 27 EXTENSION CABLE 4 to SENSOR CABLE 5 Connect the other end of the 27 EXTENSION ...

Страница 8: ...ENSION CABLE 2 and connect one end to the available sensor cable the other end to one of the two terminals at the one end of the Y ADAPTER 3 3 Take the 10 EXTENSION 4 and connect one end to the single terminal of Y ADAPTER 3 and the other end to available terminal of the previous unit s Y ADAPTER 3a 4 Repeat process for each subsequent unit 5 Place Y ADAPTERS 3 into respective electrical box 6 Plu...

Страница 9: ... into the two holes located at the bottom of the COVER PLATE 2 Push the WIRE KEY 5 up until it releases the bottom clips Pull the bottom edge away and lift the COVER PLATE 2 off 11 CONNECT OVERRIDE HOSES AC DC POWER Fig 13 1 Push the BLACK HOSE 1 into the BOTTOM HOSE CONNECTOR 2 on flush valve body and push the other end into the back of the MANUAL OVERRIDE VALVE 3 2 Push the BLUE HOSE 4 into the ...

Страница 10: ...allation is complete peel off the PROTECTIVE FILM 1 from the sensor Standing to one side block the sensor with your hand for 10 seconds Remove your hand and listen for audible click from within the valve 2 Turn on STOP VALVE 2 1 4 turn to 1 2 turn CCW and test for leaks Note Unit may flush for approximately 5 to 10 seconds when water is first turned on If flow persists turn water off and repeat st...

Страница 11: ...5 When the LED 5 stops blinking and stays ON move your hand to the desired position from sensor and hold in place until the LED 5 begins to blink again Fig 17 Note Detection Zone is 400mm 800mm Factory Setting 400mm 6 Once the SENSOR CONTROL LED 5 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set 7 Replace and secure COVER PLATE 1 ...

Страница 12: ... RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP PUSH MANUAL OVERRIDE BUTTON DOES IT RETURN TO ITS ORIGINAL POSITION FREELY RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS REPLACE PISTON SOLENOID ASSEMBLY REPEATED DOUBLE FLASH ON SENSOR R...