8
M965647 REV. 1.6 (5/17)
C
REPLACE BATTERY; Fig. 11, 11a
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in
back of FLUSH VALVE COVER
(3). Fig. 11.
2. Rotate COVER (3) to the right and pull off. Fig. 11.
3. Turn COVER (3) over and disconnect the SENSOR (4)
from the BATTERY HOLDER
(5). Remove the BATTERY
CONTAINER
(6) with BATTERY HOLDER (5) and
BATTERY
(7) inside. Fig. 11a.
4. Remove BATTERY HOLDER (5) from BATTERY
CONTAINER
(6). Fig. 11a.
5. Remove old BATTERY from BATTERY HOLDER (5).
Install the new BATTERY
(7) making sure the shape
of the BATTERY follows the shape of the BATTERY
HOLDER
(5). Fig. 11a.
6. Insert BATTERY HOLDER (5) with BATTERY into
BATTERY CONTAINER
(6). Insert BATTERY
CONTAINER
(6) into flush valve COVER (3). Fig. 11a.
7. Connect BATTERY HOLDER (5) to SENSOR (4) and
reverse the above steps to assemble flush valve.
Fig. 11a.
3
3
4
8
3
1
Fig. 11
Fig. 11a
Fig. 11b
REMOVE OLD
BATTERY
REMOVE
BATTERY
HOLDER
INSTALL
NEW
BATTERY
2
5
4
5
CR-P2
CR-P2
5
7
6
6
REMOVE OLD
LONG LIFE
POWER PACK
LONG LIFE POWER PACK
STANDARD BATTERY
INSTALL NEW
LONG LIFE
POWER PACK
8