GENERAL DESCRIPTION:

SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
Exposed Flushometer for 3/4
" Top Spud Fixtures

419 mm

(16-1/2")

292 mm

(11-1/2")

127 mm

(5")

73 mm

(2-7/8")

(1" NPT)

15˚

76mm MAX.

(3) MAX.

406 mm

(16")

292 mm

(11-1/2")

114 mm

(4-1/2")

73 mm

(2-7/8")

(1" NPT)

15˚

76mm MAX.

(3) MAX.

L-C-

L-C-

*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6

"

 (152 mm) above

fixture. Consult Codes for details.

FINISHED WALL

108-134 mm

(4-1/4" TO 5-1/4")

FOR 3/4" TOP

SPUD FIXTURES

MANUAL

OVERRIDE

BUTTON

DETECTION ZONE

400 -800 mm

(15-3/4 TO 31-1/2)

*-C-L-

152 mm MIN.

(6") MIN.

*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6

"

 (152 mm) above

fixture. Consult Codes for details.

FINISHED WALL

108-134 mm

(4-1/4" TO 5-1/4")

FOR 3/4" TOP

SPUD FIXTURES

MANUAL

OVERRIDE

BUTTON

DETECTION ZONE

400 -800 mm

(15-3/4 TO 31-1/2)

*-C-L-

152 mm MIN.

(6") MIN.

Fig. 1   (Before November 2017)

  

Roughing-in Dimensions 

 Fig. 1 

Right or Left Hand Installation

See (Section 5) for converting Flush  

Valve to Left Hand Installation.

Fig. 1A     (After November 2017)

  

Roughing-in Dimensions 

 Fig. 1 

Содержание SELECTRONIC 6062.601

Страница 1: ...278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0 125 0 25 0 5 1 0 GPF Installation Inst ru ct io n s Certified to co...

Страница 2: ...TH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 1 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 2 3 4...

Страница 3: ...8 134 mm 4 1 4 TO 5 1 4 FOR 3 4 TOP SPUD FIXTURES MANUAL OVERRIDE BUTTON DETECTION ZONE 400 800 mm 15 3 4 TO 31 1 2 C L 152 mm MIN 6 MIN Note The Critical Line C L on Vacuum Breaker must typically be...

Страница 4: ...s All piping behind the walls should be properly secured and fastened Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to operation...

Страница 5: ...from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe 2 Push WALL ESCUTCHEO...

Страница 6: ...Lubricate the O RING 3 with water if necessary Lightly tighten COUPLING NUT 4 Fig 8 Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALV...

Страница 7: ...ly 3 seconds 4 Adjust STOP VALVE 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace STOP VALVE...

Страница 8: ...move old BATTERY from BATTERY HOLDER 5 Install the new BATTERY 7 making sure the shape of the BATTERY follows the shape of the BATTERY HOLDER 5 Fig 11a 6 Insert BATTERY HOLDER 5 with BATTERY into BATT...

Страница 9: ...he program code after power connection is made 5 While the SENSOR CONTROL LED 1 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the sensor Fig 14 6 When the LED 1 stops blinking and s...

Страница 10: ...RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP...

Страница 11: ...BLY M964802 0070A SOLENOID PISTON SUBASSEMBLY Standard Battery 6063 Series A917376 0070A SET SCREW A912809 0070A O RING M964075 0070A 3 4 SWEAT ADAPTER M962926 0070A 1 SWEAT ADAPTER M964347 0020A STOP...

Отзывы: