4

     

FLUSH OUT SUPPLY LINES; Fig. 6

1.    Remove  STOP  VALVE  COVER  (1) from STOP VALVE (2).
2.  Open STOP VALVE (2) with a flat blade screwdriver.
3.  Turn on water supply to flush line of any debris or sediment.
4.  Close STOP VALVE (2) and replace STOP VALVE COVER (1)

.

5

     

LEFT OR RIGHT HAND  

INSTALLATION;  Fig. 7

The unit is shipped with adjustable tailpiece on the  

right side. If needed, the orientation can be modified  

by following the steps below.
1.
   Loosen SET SCREW (1) with 2.5mm Hex Wrench (4)  

in back of FLUSH VALVE COVER 

(2).

2.   Rotate  FLUSH  VALVE  COVER  (2) to the right and pull off.
3.   Rotate FLUSH VALVE BODY (3) 180˚.
4.   Replace COVER (2) and rotate until key engages.   

Tighten SET SCREW 

(1).

6

    

 INSTALL FLUSH VALVE; Fig. 8, 8a

1.    Insert ADJUSTABLE TAILPIECE (1) into the STOP  

VALVE 

(2). Lubricate the O-RING (3) with water if  

necessary. Lightly tighten COUPLING NUT 

(4)Fig. 8.

Important: Do not use lubricants (other than water) or  

any type of thread sealing paste or tape.
2.    Align the FLUSH VALVE BODY (5) directly above the  

VACUUM BREAKER TUBE 

(7) and VACUUM BREAKER 

COUPLING NUT 

(6)Fig. 8a

.

Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for  

the 121mm (4-3/4) dimension. Fig. 8a.
3.  Pull the VACUUM BREAKER TUBE (7) up to meet the  

threaded FLUSH VALVE BODY 

(5), hand tighten  the  

VACUUM BREAKER COUPLING NUT 

(6).  Align   all   

components of the flush valve assembly. 

Fig. 8a.

4.  Lightly tighten the COUPLING NUT 

(4) connection first,  

then the VACUUM BREAKER COUPLING NUT 

(6) and  

 finally the SPUD COUPLING NUT 

(8). Once alligned   

correctly, use a wrench to tighten couplings to make   
water tight connections. 

Fig. 8a.      

1

CLOCKWISE CLOSES

STOP VALVE

COUNTER-CLOCKWISE

OPENS STOP VALVE

REMOVE COVER

Fig. 6

2

2

4

Fig. 7

4

KEY

2

2

1

3

180˚

2

1

7
8

6

5

4

121mm,+13mm, -6mm

(4-3/4)(+1/2, -1/4)

Fig. 8

Fig. 8a

2

4

1

3

Содержание SELECTRONIC 6062.601

Страница 1: ...278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0 125 0 25 0 5 1 0 GPF Installation Inst ru ct io n s Certified to co...

Страница 2: ...TH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 1 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 2 3 4...

Страница 3: ...8 134 mm 4 1 4 TO 5 1 4 FOR 3 4 TOP SPUD FIXTURES MANUAL OVERRIDE BUTTON DETECTION ZONE 400 800 mm 15 3 4 TO 31 1 2 C L 152 mm MIN 6 MIN Note The Critical Line C L on Vacuum Breaker must typically be...

Страница 4: ...s All piping behind the walls should be properly secured and fastened Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to operation...

Страница 5: ...from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe 2 Push WALL ESCUTCHEO...

Страница 6: ...Lubricate the O RING 3 with water if necessary Lightly tighten COUPLING NUT 4 Fig 8 Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALV...

Страница 7: ...ly 3 seconds 4 Adjust STOP VALVE 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace STOP VALVE...

Страница 8: ...move old BATTERY from BATTERY HOLDER 5 Install the new BATTERY 7 making sure the shape of the BATTERY follows the shape of the BATTERY HOLDER 5 Fig 11a 6 Insert BATTERY HOLDER 5 with BATTERY into BATT...

Страница 9: ...he program code after power connection is made 5 While the SENSOR CONTROL LED 1 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the sensor Fig 14 6 When the LED 1 stops blinking and s...

Страница 10: ...RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP...

Страница 11: ...BLY M964802 0070A SOLENOID PISTON SUBASSEMBLY Standard Battery 6063 Series A917376 0070A SET SCREW A912809 0070A O RING M964075 0070A 3 4 SWEAT ADAPTER M962926 0070A 1 SWEAT ADAPTER M964347 0020A STOP...