background image

CARTRIDGE

SCREWS

HANDLE

BUSHING

SERVICE

6

CONNECT SUPPLIES

Carefully bend copper supplies to meet water supply lines using

the palms of the hands to avoid kinking.

Connect HOT water supply line to LEFT tube, and COLD water

supply line to RIGHT tube using appropriate connectors.

OR

2

TEST INSTALLED FAUCET

4

For vandal-resistant FLOW DEVICE, insert KEY teeth into

slots near outlet and turn.

Turn on water supplies and check connections for leaks.

Operate handle up and down, left and right to flush water lines

thoroughly.

Move handle down to "off" position and replace AERATOR or FLOW

DEVICE.

Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE.

Clean inlets and MANIFOLD.

Reassemble CARTRIDGE, alternately tightening screws. Replace

HOT LIMIT STOP , CAP and HANDLE. Check flow.

AERATOR may accumulate dirt causing distorted and reduced

water flow. Remove AERATOR. Clean AERATOR and FLOW

RESTRICTOR. Replace AERATOR.

If faucet drips, operate handle several times from "off" to "on".

Do not apply excessive force.

Clogged CARTRIDGE inlets may cause reduced flow in "full

on" hot or cold. To clean inlets, first turn off water supply,

then:

7 8 5 1 7

 Rev. 1.1

3

Move handle down into "off" position and remove AERATOR.

INSTALL POP-UP DRAIN

STOPPER

Push TAILPIECE down into TRAP (threaded end up).

Thread LOCKNUT, WASHER and GASKET onto

DRAIN BODY.

Apply a bead of PUTTY to underside of FLANGE.

Feed DRAIN BODY up through SINK and thread

FLANGE

 fully

 onto BODY.

Tighten LOCKNUT firmly, keeping the PIVOT ROD

pointed towards the back of the SINK.

Drop STOPPER into DRAIN BODY.

Pull TAILPIECE up and thread tightly

into DRAIN BODY.

Position EXTENSION ROD onto POP-UP ROD and

tighten THUMBSCREW.

Remove one end of CLIP from PIVOT ROD by squeezing

ends together while sliding.

Insert PIVOT ROD into second or third hole in EXTENSION

and reassemble CLIP. (EXTENSION may need to be bent.)

Adjust STOPPER height by repositioning EXTENSION and

tightening THUMBSCREW.

FLANGE

SINK

GASKET

PIVOT

ROD

DRAIN

BODY

PUTTY

WASHER

LOCKNUT

TAILPIECE

TRAP

TAILPIECE

CLIP

THUMBSCREW

POP-UP ROD

CLIP

PIVOT

ROD

EXTENSION

ROD

TRAP

EXTENSION

ROD

CARTRIDGE

SET SCREW

CAP

RETAINER

CAP

SEALS

P0P-UP

ROD

HANDLE

HOT LIMIT

STOP

ADJUSTMENT WHEN

WATER IS TOO HOT

ADJUSTMENT WHEN

WATER IS TOO COLD

PRY UPWARD TO UNLOCK

AND ROTATE COUNTER-

CLOCKWISE ONE CLICK

PRY UPWARD TO UNLOCK

AND ROTATE  CLOCKWISE 

"A"

"B"

FRONT

FRONT

By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your RELIANT faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP. 

HOT LIMIT STOP

5

Remove HANDLE, CAP and HOT LIMIT STOP. Follow "A" or "B"

to adjust maximum discharge temperature.

For toll-free information and answers to your questions, call:

1-800-442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST

IN CANADA  1-800-387-0369  (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

IN MEXICO  01-800-839-12-00

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A m e r i c a n   S t a n d a r d   I n c .

©   A S   A m e r i c a ,   I n c .   2 0 0 8

HOT LINE FOR HELP