4
7302187-100
8
9
Adjust water level to level
indicated on tank by turning
water level adjustment knob
to move float cup up or down.
A
Prime the system by flushing the
product 5 times before use to
achieve optimal performance.
B
C
VERIFY ADJUSTABLE SCREW SETUP
1. Depress trip lever handle all the way
(A)
.
2. Adjust screw on the teeter bar
(B)
so rear
frame
(C)
touches the frame stop
(D)
.
3. Return trip lever handle
(A)
to rest position.
4. Make sure hook
(E)
is fully engaged under
tab on valve body
(F)
, if not, slightly adjust
screw to make sure hook is engaged.
PROPER FLUSHING METHOD:
Be sure to fully depress the trip lever on each flush. Do not hold the trip lever down for extended periods of time as this could allow air to enter
the system which will slightly degrade performance for a few flushes.
(E)
(F)
(C)
(D)
(B)
Hook
Approximate
Water Level
Water Level Adjustment Knob
Overflow Tube
Trip Lever Rod
Float Cup
Fill Valve
Or Water
Control
Water Supply Line
Adjustable Screw
(A)