background image

M 9 6 8 5 9 9   Rev. 1. 2

5

Speed Connect™ Drain

Troubleshooting Guide

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled

as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

CABLE ADJUSTMENT PROCEDURE

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:
     •

 Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.

 

                                                                          

Fig.

 

B.

Fig.

 

A.

REMOVE
CAM

Fig.

 

E.

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. 

Fig.

 

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. 

Fig.

 

B, C.

 

Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig.

 

C.

Re-attach the Cable to the Drain Body Connection 

(2)

 by threading the Cable Connector 

(1)

 clockwise onto the

Drain Body Connection 

(2)

 and hand-tighten. 

Fig.

 

A.

STOPPER REMOVAL PROCEDURE

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE
CAM CAP

Fig.

 

F.

Fig.

 

C.

LIFT-KNOB

DOWN

STOPPER

Содержание GREEN TEA 7010.201

Страница 1: ...onto SHANKS 5 from under side of Sink Hand tighten firmly Fig B 2 1 5 3 4 6 6 5 Turn off hot and cold water supplies before beginning CAUTION HAND TIGHTEN To ensure that your installation proceeds sm...

Страница 2: ...BODY Fig B 2 4 3 TIGHTEN LOCKNUT 1 REMOVE FLANGE Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 2 2 3 3 1 1 Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel...

Страница 3: ...OP UP DRAIN to waste outlet Fig A From under mounting surface connnect FLEXIBLE INLET TUBE 1 to HOSE END 2 and tighten with wrenches Attach WEIGHTS 3 to HOSE 4 at bottom of loop in Hose 4 as shown SPO...

Страница 4: ...h a 2 5mm hex wrench 4 1 6 2 3 5 11 5 64 HEX WRENCH 2 5mm HEX WRENCH M968599 Rev 1 2 2 1 1 TEST INSTALLED FITTING With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for...

Страница 5: ...ow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPP...

Страница 6: ...e Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic L...

Страница 7: ...40 0070A PUTTY PLATE M918331 0070A M916570 YYY0A HANDLE KIT A918049 0070A ADAPTER M921371 0070A ADAPTER 7 M962552 0070A CAM ASSEMBLY M952425 YYY0A DRAIN ASSEMBLY M962621 0020A HOSE WEIGHT M962544 YYY0...