REMOTE BLOWER LOCATION OPTION 

IMPORTANT!

 

It is not necessary that the blower motor be relocated. This option is provided for the case that a particular 

installation makes this effort practical. 

NOTE:

 Relocating blower motor from factory installed location, see photo 

W, will require disassembly of air blower from mounting 

board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired 

position of air blower. Follow all instructions listed below. 

NOTE:

 Installing the blower in a remote location will reduce the system efficiency. 

NOTE:

 Relocating a blower motor still requires a service access for the blower. 

NOTE:

 All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel cable  

 

     (P/N 75405-0071A). 

A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location. 

Electrical connections should be performed by a licensed electrician. 

Choose a space as close to the bath as possible so the system works as efficiently as possible. The space must be at least 30 cubic 

feet and the blower must be mounted at least  inches above the floor and  inches minimum away from any wall. The blower must 

NOT be installed in an attic area. 

The blower motor must be located within 1 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length 

and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few 

direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes. 

Disconnect the blower from the flexible hose as shown in photo 

X. Do NOT remove the check valve manifold that is mounted to the 

underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in 

X.

Use 1 1/” PVC rigid piping and couplings to extend the blower motor location as shown in photos 

Y and Z. Detach the flexible hose 

section from the blower end and extend the air line by adding the appropriate length of PVC piping. Mount the blower in a horizontal 

direction using the mounting screws provided with the air bath system. Do NOT glue piping to either the manifold or blower. These 

couplings MUST be attached to the piping with screws as shown in photos 

Y and Z. Glue only the PVC piping and couplings needed 

to extend the air line. Let the glued couplings set overnight before attaching the blower and manifold couplings with screws. 

CAUTION: It is imperative to let the glued piping set overnight as there may be fumes from the glue that could be ignited if not 

allowed to dissipate. 

W.

X.

Y.

Z.

TYPICAL VIEW

TYPICAL VIEW

Do 

NOT move check 

valve manifold

Содержание Ellisse 2709

Страница 1: ...em To insure maximum performance and pleasure from this product please follow the instructions and cautions AS America Inc 00 All product names listed herein are trademarks of AS America Inc unless ot...

Страница 2: ...ge Safety Instructions Notice Page 3 Roughing in Reference Page 4 6 Installation and Framing Instructions Page 7 Supplied Drain Assembly and Installation Instructions Page 13 Post Installation Instruc...

Страница 3: ...ges can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your physician before using the bathtub U...

Страница 4: ...6 3 4 679mm 7 3 4 TYPICAL 197mm OUTLINE OF SKID RESISTANT SURFACE 35 3 4 908mm 13 1 4 337mm 4 102mm 71 1 2 1816mm 3 76mm FLOOR CUTOUT 9 X 19 229 X 459mm OUTLINE OF CUTOUT 70 X 40 1 4 1778 X 1022mm PRO...

Страница 5: ...GH FLOOR 1 1 2 O D TAILPIECE 508mm 20 INTEGRAL FEET WITH ATTACHED BASEBOARD 51mm 2 559mm 22 1 1 2 N P T M THREADS 35mm 1 3 8 98mm 3 7 8 C L TO OVERFLOW 102mm 4 PROVIDE ACCESS TO BLOWER FOR SERVICE ON...

Страница 6: ...l 223 L 44 Gal 167 L 19 x 49 In 483mm x 1245mm 54 1 2 x 27 In 1384mm x 686mm 14 In 356mm 36 Lbs Sq Ft 175 Kgs Sq m 25 6 45 1 GENERAL SPECIFICATIONS FOR 3572 AIR BATH SYSTEM INSTALLED SIZE WEIGHT WEIGH...

Страница 7: ...the air massage system according to the enclosed drain installation instructions Before replacing your air bath for final installation be certain that an opening has been provided in the sub floor for...

Страница 8: ...AL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations for copper conductors only Always follow local...

Страница 9: ...per installation instructions provided with the tub Bath deck support material Bathtub Waterproof Sealant UNDER DECK MOUNTING INSTRUCTIONS DRAIN STOPPER WITH ADJUSTABLE BOLT METAL STRAINER BOLT METAL...

Страница 10: ...ed dabs of 100 silicone sealant to bottom waste drain flange and press flat rubber gasket into place as shown in photos B and C 6 Apply 1 continuous bead of 100 silicone sealant to flat rubber gasket...

Страница 11: ...EN Carefully remove excess silicone from acrylic surface as directed by silicone sealant directions 9 From unit back side overflow nut should be in alignment with overflow opening as shown in photo F...

Страница 12: ...o M 14 Test fit and trim pipe as required to get overflow drain into center of overflow hole BEFORE GLUING vertical pipe into 0 degree elbow as shown in photos N 1 and N 2 15 Apply PVC cement to Verti...

Страница 13: ...ns and closes drain 21 Place drain stopper into drain waste hole as shown in photo T 22 The drain stopper should prevent water from draining out of tub when the escutcheon is in the fully counterclock...

Страница 14: ...infectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLI...

Страница 15: ...alled in an attic area The blower motor must be located within 1 feet of rigid piping from the bath air manifold This limitation is for the total pipe length and applies to any direction changes and e...

Страница 16: ...eterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for p...

Отзывы: