background image

6

754063-100 Rev. B

ROUGHING-IN REFERENCES

GENERAL SPECIFICATIONS FOR 2748

AIR MASSAGE SYSTEM

59-1/2 x 41-5/8 x 23 In. (1511 x 1057 x 584mm)

110 Lbs. (50 Kg.)

611 Lbs. (278 Kg.)

60 Gal. (227 L)

34 x 24 In. (864 x 610mm)

52 x 31 In. (1321 x 1321mm)

12-1/2 In. (318mm)

40 Lbs./Sq.Ft. (194 Kgs./Sq.m)

27.8
45.4

1.0 HP, 10 AMPS ,120V.

BLOWER

ELECTRICAL SPECIFICATIONS

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.

CUBE (FT

3

)

GENERAL SPECIFICATIONS FOR 2709 AIR BATH

69-1/4 x 38-1/2 x 19-3/4 In.(1759 x 978 x 502mm)

107 Lbs. (49 Kg.)

640 Lbs. (291 Kg.)

64 Gal. (243 L)

45 x 23 In. (1143 x 584mm)
63 x 32 In. (1600 x 813mm)

13 In. (330mm)

35 Lbs./Sq.Ft. (166 Kgs./Sq.m)

25.6
49.4

ELECTRICAL SPECIFICATIONS

1.0 HP, 10 AMPS, 120V.

BLOWER

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

GENERAL SPECIFICATIONS FOR 2742 

AIR MASSAGE SYSTEM

71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm)

115 Lbs. (52 Kg.)

690 Lbs. (313 Kg.)

69 Gal. (261 L)

41 x 21-1/2 In. (1041 x 546mm)
62 x 31-1/2 In. (1574 x 800mm)

14-1/4 In. (362mm)

 33 Lbs./Sq.Ft. (163 Kgs./Sq.m)

27.8
55.7

1.0 HP, 10 AMPS ,120V.

BLOWER

ELECTRICAL SPECIFICATIONS

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.

CUBE (FT

3

)

  60 x 36 x 22 In. (1524 x 914 x 559mm)

86 Lbs. (39 Kg.)

519 Lbs. (235 Kg.)

52 Gal. (197 L.)
38 Gal. (144 L.)

19 x 43 In. (483mm x 1092mm)

48-1/2 x 27 In. (1232mm x 686mm)

14 In. (356mm)

35 Lbs./Sq. Ft. (169 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 3571

AIR BATH SYSTEM

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

ELECTRICAL SPECIFICATIONS

1.0 HP, 10 AMPS, 120V.

BLOWER

  66 x 36 x 22 In. (1676 x 914 x 559mm)

100 Lbs. (45 Kg.)

592 Lbs. (269 Kg.)

59 Gal. (223 L.)
44 Gal. (167 L.)

19 x 49 In. (483mm x 1245mm)

54-1/2 x 27 In. (1384mm x 686mm)

14 In. (356mm)

36 Lbs./Sq. Ft. (175 Kgs/Sq. m.)

25.6
45.1

GENERAL SPECIFICATIONS FOR 3572

AIR BATH SYSTEM

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

ELECTRICAL SPECIFICATIONS

1.0 HP, 10 AMPS, 120V.

BLOWER

  72 x 36 x 22 In. (1829 x 914 x 559mm)

115 Lbs. (52 Kg.)

665 Lbs. (302 Kg.)

66 Gal. (250 L.)
49 Gal. (185 L.)

19 x 55 In. (483mm x 1397mm)

60-1/2 x 27 In. (1537mm x 686mm)

14 In. (356mm)

37 Lbs./Sq. Ft. (175 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 3573

AIR BATH SYSTEM

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

ELECTRICAL SPECIFICATIONS

1.0 HP, 10 AMPS, 120V.

BLOWER

  59-3/4 x 42 x 22 In. (1518 x 1060 x 559mm)

115 Lbs. (52 Kg.)

656 Lbs. (298 Kg.)

65 Gal. (246 L.)
47 Gal. (178 L.)

24-1/2 x 42 In. (622mm x 1067mm)

48 x 33 In. (1219mm x 838mm)

14 In. (356mm)

38 Lbs./Sq. Ft. (185 Kgs/Sq. m.)

27.8
47.4

GENERAL SPECIFICATIONS FOR 3574

AIR BATH SYSTEM

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

ELECTRICAL SPECIFICATIONS

1.0 HP, 10 AMPS, 120V.

BLOWER

  72 x 42 x 22 In. (1829 x 1067 x 559mm)

127 Lbs. (58 Kg.)

785 Lbs. (356 Kg.)

79 Gal. (299 L.)
58 Gal. (219 L.)

22-1/2 x 54 In. (572mm x 1372mm)

60 x 33 In. (1524mm x 838mm)

14 In. (356mm)

37 Lbs./Sq. Ft. (185 Kgs/Sq. m.)

25.6
49.4

GENERAL SPECIFICATIONS FOR 3575

AIR BATH SYSTEM

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

ELECTRICAL SPECIFICATIONS

1.0 HP, 10 AMPS, 120V.

BLOWER

ELLISSE OVAL 

MODEL 2709 AIR BATH

 TOWN SQUARE

®

 5' x 42" 

MODEL 2748 AIR BATH

 TOWN SQUARE

®

 6' x 42" 

MODEL 2742 AIR BATH

 GREEN TEA™ 5' x 36" 

MODEL 3571 AIR BATH

GREEN TEA™ 6' x 36" 

MODEL 3573 AIR BATH

GREEN TEA™ 5' x 42" 

MODEL 3574 AIR BATH

 GREEN TEA™ 5-1/2' x 36" 

MODEL 3572 AIR BATH

 GREEN TEA™ 6' x 42" 

MODEL 3575 AIR BATH

Содержание Ellisse 2709

Страница 1: ...em To insure maximum performance and pleasure from this product please follow the instructions and cautions AS America Inc 00 All product names listed herein are trademarks of AS America Inc unless ot...

Страница 2: ...ge Safety Instructions Notice Page 3 Roughing in Reference Page 4 6 Installation and Framing Instructions Page 7 Supplied Drain Assembly and Installation Instructions Page 13 Post Installation Instruc...

Страница 3: ...ges can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your physician before using the bathtub U...

Страница 4: ...6 3 4 679mm 7 3 4 TYPICAL 197mm OUTLINE OF SKID RESISTANT SURFACE 35 3 4 908mm 13 1 4 337mm 4 102mm 71 1 2 1816mm 3 76mm FLOOR CUTOUT 9 X 19 229 X 459mm OUTLINE OF CUTOUT 70 X 40 1 4 1778 X 1022mm PRO...

Страница 5: ...GH FLOOR 1 1 2 O D TAILPIECE 508mm 20 INTEGRAL FEET WITH ATTACHED BASEBOARD 51mm 2 559mm 22 1 1 2 N P T M THREADS 35mm 1 3 8 98mm 3 7 8 C L TO OVERFLOW 102mm 4 PROVIDE ACCESS TO BLOWER FOR SERVICE ON...

Страница 6: ...l 223 L 44 Gal 167 L 19 x 49 In 483mm x 1245mm 54 1 2 x 27 In 1384mm x 686mm 14 In 356mm 36 Lbs Sq Ft 175 Kgs Sq m 25 6 45 1 GENERAL SPECIFICATIONS FOR 3572 AIR BATH SYSTEM INSTALLED SIZE WEIGHT WEIGH...

Страница 7: ...the air massage system according to the enclosed drain installation instructions Before replacing your air bath for final installation be certain that an opening has been provided in the sub floor for...

Страница 8: ...AL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations for copper conductors only Always follow local...

Страница 9: ...per installation instructions provided with the tub Bath deck support material Bathtub Waterproof Sealant UNDER DECK MOUNTING INSTRUCTIONS DRAIN STOPPER WITH ADJUSTABLE BOLT METAL STRAINER BOLT METAL...

Страница 10: ...ed dabs of 100 silicone sealant to bottom waste drain flange and press flat rubber gasket into place as shown in photos B and C 6 Apply 1 continuous bead of 100 silicone sealant to flat rubber gasket...

Страница 11: ...EN Carefully remove excess silicone from acrylic surface as directed by silicone sealant directions 9 From unit back side overflow nut should be in alignment with overflow opening as shown in photo F...

Страница 12: ...o M 14 Test fit and trim pipe as required to get overflow drain into center of overflow hole BEFORE GLUING vertical pipe into 0 degree elbow as shown in photos N 1 and N 2 15 Apply PVC cement to Verti...

Страница 13: ...ns and closes drain 21 Place drain stopper into drain waste hole as shown in photo T 22 The drain stopper should prevent water from draining out of tub when the escutcheon is in the fully counterclock...

Страница 14: ...infectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLI...

Страница 15: ...alled in an attic area The blower motor must be located within 1 feet of rigid piping from the bath air manifold This limitation is for the total pipe length and applies to any direction changes and e...

Страница 16: ...eterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for p...

Отзывы: