TEST INSTALLED FAUCET
SERVICE
• Move HANDLE
(1)
into “off” position.
• Unthread SPRAY HOSE
(3)
from SPRAY
(2)
.
• Turn on water supplies and check connections for leaks.
• Hold HOSE END
(3)
in sink and operate HANDLE
(1)
on and off,
hot and cold to flush water lines thoroughly. Replace SPRAY
(2)
.
• Pull SPRAY
(2)
out and check hose and supply connections
for leaks. Check that SPRAY HOSE
(3)
and WEIGHT
(4)
slide
up and down freely and do not interfear with supplies or waste
outlet plumbing.
• Check all drain connections for leaks.
• Move HANDLE
(1)
to “off” position.
•
Clogged CARTRIDGE outlets or inlets may cause
reduced flow.
To clean, first turn off water supply then:
• Loosen and remove LEVER HANDLE
(1)
. Loosen
HANDLE SCREW
(2)
with 2.5mm Hex Wrench and
then pull HANDLE BASE
(3)
off.
• Unscrew ESCUTCHEON CAP
(4)
. Unscrew the
CARTRIDGE NUT
(5)
.
• Remove CARTRIDGE
(6)
. Clean inlets of
CARTRIDGE
(6)
and MANIFOLD
(7)
.
• Reassemble CARTRIDGE
(6)
. Replace CARTRIDGE
NUT
(5)
, CAP
(4)
and HANDLE assembly, check flow.
•
If SPOUT (7) leaks at swivel point the O-RINGS (8)
need to be replaced. To remove SPOUT (7):
• Loosen the SPOUT SET SCREW
(9)
with
a 3mm Hex wrench.
• Rotate the SPOUT
(7)
side to side while pulling
upward to remove SPOUT
(7)
from faucet body.
• Replace the defective parts, grease O-RINGS
(8)
then push SPOUT
(7)
back into position.
Tighten SET SCREW
(9)
.
• Check that SPOUT
(7)
rotates freely and
does not leak at the swivel point.
5
4
M965559 Rev. 1.5 (3/15)
1
2
5
3
3
4
HOT & COLD SUPPLIES
9
8
11
3mm
HEX WRENCH
12
1
3
4
5
6
CLEAN
7
REMOVE
INSTALL
10
2