background image

WATER SUPPLY CONNECTIONS

   0

     1

     2

    3

    4

    

 5

    

 6

    

If faucet drips, operate HANDLE 

(4)

 several times from

"off" to "on." Do not apply excessive force.

4

3

HAND SPRAY INSTALLATION

5

SERVICE

FOR MODELS WITH HAND SPRAY ONLY:

ALL MODELS:

Feed SPRAY HOSE 

(5)

 through SPRAY HOLDER 

(1)

 and attach COUPLING

NUT 

(4)

 of SPRAY HOSE 

(5)

 to MOUNTING STUD 

(3)

. Tighten COUPLING

NUT 

(4) 

firmly.

Make certain that SPACER WASHER 

(6)

 and RUBBER WASHER 

(7)

are attached to SPRAY HOSE 

(5)

 and thread SPRAY HEAD 

(9) 

to

NUT 

(8)

. Tighten COUPLING NUT 

(8) 

firmly. 

Place SPRAY HOLDER 

(1)

 into the appropriate mounting hole,

assemble WING NUT 

(2)

 onto shank of SPRAY HOLDER 

(1)

from underside of sink and secure by tighting WING NUT 

(2)

.

M66240 REV.1.1

1

8

9
7

6

2

Note: If additional supply length is required, installer must purchase
additional parts separately.

Bend 3/8” SUPPLY TUBES to meet water supplies valves.

Use palm of hand to support TUBES while bending to avoid kinking.

Connect inlet TUBES to water supplies with appropriate connectors.

Connect left TUBE to HOT water supply, and the right TUBE to the

COLD water supply.

COMPRESSION

NUT

3/8 O.D.

SUPPLIES

FERRULE

COLD

HOT

3

5

1

2

3

4

5

6

7

8

12

13

14

9

10

11

4

AERATOR 

(14)

 may accumulate dirt causing distorted

and reduced water flow.  Remove, clean, and replace

AERATOR 

(14)

.

Clogged CARTRIDGE 

(1)

 inlets or outlets

may cause reduced flow in "full on,"

hot or cold.  To clean ports, first turn

off Hot and Cold water supplies, then:

Remove BUTTON 

(2)

, loosen HANDLE

SCREW 

(3)

 and pull HANDLE 

(4)

 off.

Remove ESCUTCHEON CAP 

(5)

.

Lift CARTRIDGE 

(1)

 off

MANIFOLD 

(7)

, remove

SEALS 

(8)

.  Clean ports,

SEALS 

(8)

, FLOW

REGULATOR 

(9)

 and

MANIFOLD 

(7)

.

If hand spray water

flow is restricted, lift

DIVERTER 

(10)

 using long-

nose pliers.  Clean

and replace.

Replace ESCUTCHEON CAP 

(5)

, HANDLE 

(4)

, and tighten HANDLE

SCREW 

(3)

.  Replace PLUG BUTTON 

(2)

.

To replace SPOUT SEALS 

(11)

, remove CARTRIDGE 

(1)

as described on the left, then:

Remove three MOUNTING SCREWS 

(6)

.

Insert SEALS 

(8)

 back into CARTRIDGE 

(1)

.

Make certain larger diameter of FLOW

REGULATOR 

(9)

 faces inside CARTRIDGE 

(1)

.

Place CARTRIDGE 

(1)

 onto MANIFOLD 

(7)

 and

alternately tighten the three MOUNTING SCREWS 

(6)

.

Slip SPOUT 

(12)

 off MANIFOLD 

(7)

 and replace LIP

SEALS 

(11)

 and BEARING RING 

(13)

. Make certain

SEALS 

(11)

 are well lubricated.

For assembly, proceed as above in reverse order.