American Standard CENTURION 2371 Скачать руководство пользователя страница 7

754407-100 Rev. B

7

SUGGESTED WHIRLPOOL / BATH 

INSTALLATION METHOD

SECURE THE BATH TO THE STUDS AS SHOWN 

FOR WOOD OR STEEL STUD CONSTRUCTION. 

TYPICAL FLANGE MOUNTING DETAIL

UNLESS AN ACCESS OPENING OF AT LEAST

12" x 24" (305 x 610mm) IS PROVIDED,

WARRANTY SERVICE WILL NOT BE PERFORMED.

1

(4mm)

WHIRLPOOL

ACCESS PANEL

UNDER DECK MOUNTING INSTRUCTIONS

Please note that care must be taken to protect the surface of the tub 

during all aspects of the installation.

Do not drill or cut the bath deck with the tub directly beneath it as 

damage to the tub may result.

1.   Install the tub per the installation instructions provided with the 

unit.

.   Prepare the bath deck support structure per the local codes. 

Note - the bath deck must be self supporting.

.   Cut bath deck to your specifications.

4.   Place the bath deck in position and trace the opening on the tub 

with a soft pencil. Do not drill or cut the bath deck with the tub 

directly beneath it as damage to the tub may result.

5.   Remove the bath deck and apply a generous bead of waterproof 

sealant on the outer edge of the traced line.

.   Replace the bath deck and secure it into place.

7.   Apply additional sealant along the tub and bath deck interface as 

necessary to ensure a watertight seal.

.   Remove excess sealant per the manufacturer's instructions.

Finished bath deck 

surface material must be 

self-supporting and 

secured per local codes

Tub support structure 

per installation 

instructions provided 

with the tub 

Bath deck 

support material

Bathtub

Waterproof 

Sealant

STUD

WATERPROOF DRYWALL 
OR CEMENT BOARD

WATERPROOF DRYWALL 

OR CEMENT BOARD

TILE

SEALANT

TUB

ROOFING NAIL

   1 x  (5 x 7mm) WOOD

STRINGER FULL LENGTH

  1 x  (5 x 7mm) WOOD

STRINGER FULL LENGTH

STEEL

STUD

WASHER

TILE

SEALANT

TUB

4" (10mm)

DRYWALL

SCREW 

WOOD 

STUDS

STEEL

STUDS

TYPICAL INSTALLATION - CORNER 

PIER CUTOUTS

L

Drain

End

17" R

(4mm)

C

-5/1" R

(44mm)

1" R

(4mm)

40"

(101mm)

4"

(4mm)

70"

(177mm)

57-1/4"

(1454mm)

45-/4"

(11mm)

10˚

5"

(5mm)

Installation of a whirlpool in a platform requires a cutout.

 

Many whirlpools need only a rectangular cutout. Some whirlpools 

require a more elaborate cutout. Illustrated below are diagrams 

for those cutouts. 

MODEL 2351

MODEL 2383

Содержание CENTURION 2371

Страница 1: ...ed fittings and electrical connections To insure maximum performance and pleasure from this product please follow the instructions and cautions CORNER DUET W SEAT 60 x 60 MODEL 2351 CENTURION 6 x 36 MODEL 2371 CONTEMPO OVAL MODEL 2383 FREE SPIRIT 6 x 54 MODEL 2466 AS Americas Inc 010 All product names listed herein are trademarks of AS Americas Inc unless otherwise noted FOR AFTER SALES SERVICE CA...

Страница 2: ... Information Page 4 Optional Components Page 4 Specifications Page 4 Roughing in Reference Page 5 Framing and Support Instructions Page Mounting Instructions Page 7 Electrical Connections Page Drain Connection and System Test Page Care and Cleaning Page Warranty Page 10 ...

Страница 3: ...cribed in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should...

Страница 4: ... motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others For electrical requirements refer to section titled Whirlpool Electrical Installation Instructions Check for availability of optional American Standard wall tiling bead required for recess installation Protect all finished ...

Страница 5: ...A PTS CUBE FT3 1 4 HPR 9 7 AMPS 120V PUMP GENERAL SPECIFICATIONS FOR 2383 72 x 42 x 25 1 2 In 1829 x 1067 x 648mm 100 Lbs 45 Kg 841 Lbs 382 Kg 89 Gal 337 L 41 Gal 155 L 48 x 26 1 2 In 1219 x 673mm 60 3 4 x 35 3 4 In 1543 x 908mm 18 1 2 In 470mm 40 Lbs Sq Ft 196 Kgs Sq m 17 2 48 ELECTRICAL SPECIFICATIONS INSTALLED SIZE WEIGHT WEIGHT w WATER GAL TO OVERFLOW MIN OPERATING GAL BATHING WELL AT SUMP BAT...

Страница 6: ... shadowed and location dimensions The drain overflow of the bath extends below the bottom of the bath Note that this requires a cutout in the floor The floor structure beneath the bath must be able to support a total weight of bath water and bather Refer to Table 1 under total weight for your model Remove the whirlpool and attach a 1 x 4 stringer to the studs with the top of the stringer touching ...

Страница 7: ...bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line Replace the bath deck and secure it into place 7 Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal Remove excess sealant per the manufacturer s instructions Finished bath deck surface material must be self supporting and secured per local codes Tub su...

Страница 8: ...e recommendations for copper conductors only Always follow local and national electrical codes Motor Hi Performance Rating 2 1 H P 1 4 H P and 1 25 H P 50 100 115V Power Line 150 200 12 10 8 8 The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three wire circuit from the electric...

Страница 9: ...e and hang to dry Allowing bath mat to dry in the tub may cause surface damage Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Do not use wire bru...

Страница 10: ...nstallation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specific legal rights You may have other legal rights that vary from state to state For service under this warranty you should contact the following By Telephone 1 800 442 1902 If inspection of this AS American Inc ...

Отзывы: