754407-100 Rev. B
5
ROUGHING-IN REFERENCES
CORNER DUET WITH SEAT 60" x 60" (MODEL 2351)
CONTEMPO OVAL (MODEL 2383)
FREE SPIRIT 6' x 54" (MODEL 2466)
CENTURION 6' x 36" (MODEL 2371)
GENERAL SPECIFICATIONS FOR 2351
84-1/2 x 60-1/2 x 20-1/2 In.(2146 x 1537 x 521mm)
145 Lbs. (66 Kg.)
895 Lbs. (406 Kg.)
90 Gal. (341 L)
40 Gal. (151 L)
55-1/2 x 28-3/4 In. (1410 x 730mm)
62 x 49-3/4 In. (1575 x 1264mm)
13-3/8 In. (340mm)
25 Lbs./Sq.Ft. (123 Kgs./Sq.m)
27.5
52
ELECTRICAL SPECIFICATIONS
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
1.4 HPR, 9.7 AMPS, 120V.
PUMP
GENERAL SPECIFICATIONS FOR 2371
72 x 36 x 21-3/4 In.(1829 x 914 x 552mm)
100 Lbs. (45 Kg.)
625 Lbs. (283 Kg.)
63 Gal. (238 L)
47 Gal. (178 L)
54 x 19-1/4 In. (1372 x 489mm)
63-1/4 x 29-1/2 In. (1607 x 749mm)
15-1/2 In. (394mm)
35 Lbs./Sq.Ft. (169 Kgs./Sq.m)
17.2
38
ELECTRICAL SPECIFICATIONS
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
1.4 HPR, 9.7 AMPS, 120V.
PUMP
GENERAL SPECIFICATIONS FOR 2383
72 x 42 x 25-1/2 In.(1829 x 1067 x 648mm)
100 Lbs. (45 Kg.)
841 Lbs. (382 Kg.)
89 Gal. (337 L)
41 Gal. (155 L)
48 x 26-1/2 In. (1219 x 673mm)
60-3/4 x 35-3/4 In. (1543 x 908mm)
18-1/2 In. (470mm)
40 Lbs./Sq.Ft. (196 Kgs./Sq.m)
17.2
48
ELECTRICAL SPECIFICATIONS
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
1.4 HPR, 9.7 AMPS, 120V.
PUMP
GENERAL SPECIFICATIONS FOR 2466
72 x 54 x 23-1/4 In.(1829 x 1372 x 591mm)
130 Lbs. (59 Kg.)
1213 Lbs. (550 Kg.)
130 Gal. (492 L)
92 Gal. (348 L)
50 x 42 In. (1270 x 1067mm)
64-1/2 x 43-3/4 In. (1638 x 111mm)
15-1/2 In. (394mm)
45 Lbs./Sq.Ft. (219 Kgs./Sq.m)
27.5
62
ELECTRICAL SPECIFICATIONS
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
2.1 HPR, 13.5 AMPS, 120V.
PUMP
34"
(864mm)
59-3/4"
(1518mm)
59-3/4"
(1518mm)
60-1/2"
(1537mm)
45-1/2"
(1156mm)
84-1/2"
(2146mm)
22-1/4"
(565mm)
12-5/8
(321mm)
PUMP
LOCATION
27-1/2"
(699mm)
PUMP
LOCATION
72"
(1829mm)
36"
(914mm)
10"
(254mm)
6"
(152mm)
15-3/4"
(400mm)
21"
(533mm)
72"
(1829mm)
42"
(1067mm)
PUMP
LOCATION
36"
(914mm)
72"
(1829mm)
PUMP
LOCATION
54"
(1372mm)
27"
(686mm)