background image

754407-100 Rev. B

INSTALLATION AND FRAMING INSTRUCTIONS

The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure 
roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump 
and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used 
as the primary access opening.

TYPICAL PIER TYPE INSTALLATION

AS DESIRED

F

CUTOUT

AS DESIRED

G

CUTOUT

C

4

(10 mm)

1

(05 mm)

MOUNTING 

SURFACE

WATERPROOF
 SEALANT

BATH

TYPICAL RECESS INSTALLATION

4

(10 mm)

1

(05 mm)

C

E

D

W

LEVELING
STRINGERS

TILE

TILE

BEAD

STRIP

LEVELING STRINGER 

1 x 4 (not for support)

BATH

ADHESIVE

SEALANT

WALLBOARD

NOTE

: Tile bead kit not included and  

            must be purchased separately.

C

TYPICAL INSTALLATION

FIGURE 1

     

Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet.  Secure the shims using construction 

adhesive, silicone, mortar or equivalent materials.  While not a necessity, the use of a foundation base consisting of cement, mortar, or grout 
will help provide a solid and secure installation.

.

 

Install drain components to the whirlpool following the drain installation instructions.  Before replacing your whirlpool for final installation, be 

certain that an opening has been provided in the sub-floor for the drain.  See the roughing-in drawing and Table 1 for suggested opening 
size (shadowed) and location dimensions. The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a 
cutout in the floor.

 

     
    

The floor structure beneath the bath must be able to support a total weight of bath, water, and bather. Refer to Table 1 under total weight for 

your model.

.

 

Remove the whirlpool and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line. 

    The rim of the bath 

must not

 support weight.

1.

 

Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary. 

Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).

!

!

!

ACCESS PANEL MUST BE LOCATED 
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR 
END FOR SERVICE.

ACCESS PANEL MUST BE LOCATED 
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON 
PUMP/MOTOR END FOR SERVICE.

FOR E & D DIMENSIONS SEE 

TABLE 1

 ON PAGE 5.

FOR G & F DIMENSIONS SEE 

TABLE 1

 ON PAGE 5.

NOTE:

 

FRONT EDGE 
OF BATH MUST 
BE SUPPORTED 
BY STUD WALL OR 
AMERICAN STANDARD 
APRON KIT

    

The rim of the bath 

must not

 support weight. If foundation base is used, allow the bedding material to completely harden before applying weight 

to the rim or bottom of the bath.  Any finish material such as tile or wall board must be self-supporting if it contacts the deck of the bath.

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm) 

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm) 

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

(EXCEPT 2425 WHERE APRON IS PRIMARY ACCESS OPENING)

ACCESS PANELS NOT REQUIRED 

FOR BATH TUBS.

ACCESS PANELS NOT REQUIRED 

FOR BATH TUBS.

Содержание CENTURION 2371

Страница 1: ...ed fittings and electrical connections To insure maximum performance and pleasure from this product please follow the instructions and cautions CORNER DUET W SEAT 60 x 60 MODEL 2351 CENTURION 6 x 36 MODEL 2371 CONTEMPO OVAL MODEL 2383 FREE SPIRIT 6 x 54 MODEL 2466 AS Americas Inc 010 All product names listed herein are trademarks of AS Americas Inc unless otherwise noted FOR AFTER SALES SERVICE CA...

Страница 2: ... Information Page 4 Optional Components Page 4 Specifications Page 4 Roughing in Reference Page 5 Framing and Support Instructions Page Mounting Instructions Page 7 Electrical Connections Page Drain Connection and System Test Page Care and Cleaning Page Warranty Page 10 ...

Страница 3: ...cribed in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should...

Страница 4: ... motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others For electrical requirements refer to section titled Whirlpool Electrical Installation Instructions Check for availability of optional American Standard wall tiling bead required for recess installation Protect all finished ...

Страница 5: ...A PTS CUBE FT3 1 4 HPR 9 7 AMPS 120V PUMP GENERAL SPECIFICATIONS FOR 2383 72 x 42 x 25 1 2 In 1829 x 1067 x 648mm 100 Lbs 45 Kg 841 Lbs 382 Kg 89 Gal 337 L 41 Gal 155 L 48 x 26 1 2 In 1219 x 673mm 60 3 4 x 35 3 4 In 1543 x 908mm 18 1 2 In 470mm 40 Lbs Sq Ft 196 Kgs Sq m 17 2 48 ELECTRICAL SPECIFICATIONS INSTALLED SIZE WEIGHT WEIGHT w WATER GAL TO OVERFLOW MIN OPERATING GAL BATHING WELL AT SUMP BAT...

Страница 6: ... shadowed and location dimensions The drain overflow of the bath extends below the bottom of the bath Note that this requires a cutout in the floor The floor structure beneath the bath must be able to support a total weight of bath water and bather Refer to Table 1 under total weight for your model Remove the whirlpool and attach a 1 x 4 stringer to the studs with the top of the stringer touching ...

Страница 7: ...bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line Replace the bath deck and secure it into place 7 Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal Remove excess sealant per the manufacturer s instructions Finished bath deck surface material must be self supporting and secured per local codes Tub su...

Страница 8: ...e recommendations for copper conductors only Always follow local and national electrical codes Motor Hi Performance Rating 2 1 H P 1 4 H P and 1 25 H P 50 100 115V Power Line 150 200 12 10 8 8 The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three wire circuit from the electric...

Страница 9: ...e and hang to dry Allowing bath mat to dry in the tub may cause surface damage Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Do not use wire bru...

Страница 10: ...nstallation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specific legal rights You may have other legal rights that vary from state to state For service under this warranty you should contact the following By Telephone 1 800 442 1902 If inspection of this AS American Inc ...