ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

BLACK

WHITE

1 2 0   V A C

G N D .

S E P E R A T E  

1 5   A M P

G F C I   O U T L E T

W H I R L P O O L   M O U N T E D

A I R   S W I T C H   O R

W A L L   T I M E R

 

E L E C T R I C A L   I N S T A L L A T I O N

P U M P / M O T O R

752481-100 Rev. H

ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other 
applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1. DANGER:  RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2. Grounding is required.  The unit should be installed by a licensed electrician and grounded.

3. Install to permit access for servicing.

4. All building materials and wiring should be routed away from the pump body and heater (if equipped). 

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit.  The circuit should be hard-wired from the 
electrical power supply panel.  The circuit must be a three (3) wire circuit from the electrical supply panel.  A grounded 
neutral wire and a third wire, earth ground, are essential.

(3)

Содержание Cadet 2770.XXXW Series

Страница 1: ...otherwise noted HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS CADET 5 x 32 WHIRLPOOL BATHING POOL 2770 XXXW SERIES List of Optional Components not included Tile Bead Kit 751755 100 Apron Kit see your American Standard Distributor List of Required Components not included Drain 1583 470 Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Level Tape Measure Pipe ...

Страница 2: ...ions for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron should not be used as the primary access opening 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary Mark the final position of the underside of the de...

Страница 3: ... including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on...

Страница 4: ... be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base pain...

Отзывы: