INSTALLATION INSTRUCTIONS
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any
shipping damage. If such damage is found, report it to
your vendor immediately.
After inspection and during installation, protect the bath
from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit
and check for leaks.
If a whirlpool, do not make modifications to the whirlpool
system or remove pump from factory mounting. This
could adversely affect the safety and performance of the
whirlpool and void the warranty. Do not handle or move
the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided
with the bath and must be ordered separately. Framing
and enclosing materials are provided by others. Check
for availability of optional American Standard wall tiling
bead (required for recess installations).
Protect all finished surfaces of the whirlpool during
construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping har-
ness at any time.
NOTE: Deck-mounted fittings are not recommended.
752481-100 Rev. H
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
CADET™ 5' x 32"
WHIRLPOOL/BATHING POOL
2770.XXXW SERIES
List of Optional Components (not included):
• Tile Bead Kit 751755-100*
• Apron Kit*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
59-7/8 x 31-3/4 x 19-3/4 In.
(1521mm x 806 mm x 502mm)
85 Lbs. (39 Kg.)
535 Lbs. (243 Kg.)
54 Gal. (204 L.)
49 Gal. (186 L.)
20 x 40 In. (508mm x 1016mm)
53-1/2 x 26 In. (1359mm x 699mm)
14 In. (356mm)
41 Lbs./Sq. Ft. (197 Kgs/Sq. m.)
15.6
29.6
GENERAL SPECIFICATIONS FOR 2770 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.1 HP, 9.9 AMPS, 120V.
SYSTEM I PUMP
464 mm
(18-1/4)
38 mm
(1-1/2)
502 mm
(19-3/4)
1-1/2 O.D.TAILPIECE
INTEGRAL
SUPPORT
FEET
■
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
70mm
(2-3/4)
305 mm
(12)
OPTIONAL TO
INISHED FLOOR
SUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
102 mm
(4)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
70 mm
(2-3/4)
117 mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
1521 mm
(59-7/8)
806 mm
(31-3/4)
OUTLINE OF CUTOUT
1483 mm x 768 mm
(58-3/8 X 30-1/4 )
403 mm
(15-7/8)
222 mm
(8-3/4)
305 mm
(12)
60mm
(2-3/8)
(8) JETS
CUTOUT IN FLOOR
FOR DRAIN
PUMP
FINISHED
WALL
19 mm
(3/4)
229 mm
(9)
C/L OF
SUPPLIES
C/L OF DRAIN
EE FITTING
PECS FOR
MENSIONS
(2) AIR VALVES
ON/OFF
SWITCH
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS