ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack
upon completion of work.

 

HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

WARNING:

Installer’s Guide

General Information

1

Installation Limitations & Recommendations

1-2

Unit Installation

2-5

Installation on a concrete wall

2-3

Installation on a stud wall

3

Installation on floor joists

3

Installation on roof rafters

3-4

Duct Connections

6-7

Electrical Controls

7

Percent Timer Control

8

Push Button Point-of-use Control

8-9

Checkout Procedure

10

Contents

A. GENERAL INFORMATION

WARNING

!

THIS INFORMATION IS FOR USE BY INDIVIDUALS
HAVING ADEQUATE BACKGROUNDS OF ELECTRICAL
AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO
REPAIR A CENTRAL AIR CONDITIONING PRODUCT
INCLUDING AN ERV MAY RESULT IN PERSONAL IN-
JURY AND/OR PROPERTY DAMAGE. THE MANUFAC-
TURER OR SELLER CANNOT BE RESPONSIBLE FOR
THE INTERPRETATION OF THIS INFORMATION, NOR
CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH
ITS USE.

CAUTION

!

To prevent shortening its service life, the ERV should not
be used during the finishing phases of construction.
Compounds used in construction and construction dust
may cause rapid deterioration of the cabinet and internal
components. To avoid damage keep drywall spray,
construction dust, etc from entering the air stream of the
unit.

These instructions do not cover all variations in systems or
provide for every possible contingency. Should further
information be desired or particular problems arise which are
not covered sufficiently by this manual, contact your local
distributor or the manufacturer as listed on the ERV name-
plate.

BEFORE YOU BEGIN THE INSTALLATION
Check carefully for any shipping damage. This must be
reported to and claims made against the transportation
company immediately. Open carton, remove packing
material, loose parts and ship-with literature.  Check to be
sure all major components are in the unit. Any missing
parts should be reported to your supplier at once, and
replaced with authorized parts only.

18-HE58D1-3

Energy Recovery Ventilator (ERV)

*ERVR100A9P00A
*ERVR200A9P00A
*ERVR300A9P00A

*First letter may be "A" or "T"

Figure 1

Содержание AERVR100A9P00A

Страница 1: ...ION NOR CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE CAUTION To prevent shortening its service life the ERV should not be used during the finishing phases of construction Compounds used in c...

Страница 2: ...uctural alterations necessary for installation must comply with all applicable building health and safety code requirements ERV LOCATION CONSIDERATIONS Select a location to install the ERV with the ob...

Страница 3: ...S Access Door Swings Open Down The unit may be fastened directly to floor joists using the hanging bracket and integral flange Mount as described for installation on a concrete foundation wall except...

Страница 4: ...The unit may be installed in a variety of positions EXCEPT as noted in Figure 6d APPROVED MOUNTING POSITIONS HINGE HINGE Figure 6a Hinges on Bottom HINGE HINGE Figure 6b Hinges on Right HINGE HINGE Fi...

Страница 5: ...fan power humidifier Do not install a by pass humidifier as it can freeze based on the installation outdoor temperature and homeowner thermostat setback requirements APPROVED INSTALLATIONS I Separate...

Страница 6: ...ing flexible duct band or tape the inner duct liner to the inner flange of appropriate collar Drive a sheet metal screw through the liner to secure the duct spiral wire to the collar Straighten insula...

Страница 7: ...tall hood and ductwork through penetration See figure 13 for sealing duct penetration and duct collar Fill and seal COMPLETELY with Expanded Foam Figure 13 DUCTWORK CONNECTING ERV TO INDOOR TERMINATIO...

Страница 8: ...ble from your local distributor MicroSoft Excel is required to run this program The calculator input can accept a minimum ventilation airflow requirement per local code or calculate the minimum airflo...

Страница 9: ...ain and the unit will run 40 minutes A third press provides for 60 minutes of operation Percent Timer Control does not need to be on for the PB Control to operate the ERV unit You can cancel a cycle a...

Страница 10: ...o 10 unit should start and run for approximately six minutes 11 Go to outside of building and check for airflow at inlet and outlet hoods Check that weatherhood screens are in place and clean Make sur...

Страница 11: ...18 HE58D1 3 11 Installer s Guide...

Страница 12: ...policy of continuous product and product data improvement it reserves the right to change design and specifications without notice AmericanStandardInc 6200TroupHighway Tyler TX75711 Formoreinformation...

Отзывы: