Electric Shock Hazard
To avoid the risk of electrical shock, personal injury or death, verify electrical
power is turned off at the breaker box & gas supply is turned off until the
cook top is installed.
WARNING
!
ELECTRICAL REQUIREMENTS
There is no connection necessary beyond plugging the unit into a polarized, grounded, 120 VOLT, 60Hz, 15 Amp circuit. The
minimum of 102 VAC is required for proper operation of gas ignitions. This circuit must be grounded and properly polarized.
The unit is equipped with a 16-STP2 Power Cord.
GAS CONNECTION
The gas supply (service) line must be the same size or greater then the inlet line of the appliance. This cook top uses a 1/2" ID NPT
inlet. Sealant on all pipe joints must be resistive to LP gas.
The cook top is designed specifically for natural gas or liquid propane (LP) gas. Before beginning installation, verify that the model is
compatible with the intended gas supply.
Manual Shut-off Valve:
This installer-supplied valve must be installed in the gas service line before the appliance in the gas stream and in a location where it
can be reached quickly in the event of an emergency. Any opening behind the cook top should be sealed.
Important:
Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company.