American Range GREEN FLAME RESTAURANT AR-GF Series Скачать руководство пользователя страница 11

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

7

Owner’s Manual

      AR-GF Series Ranges

GAS CONNECTION

Be certain the appliance being installed is correct for the gas service being provided.  Refer to the appliance data plate for the gas 

supply requirements.

A manual gas shut-off valve must be remotely installed and easily accessible in the adjacent cabinet.  The regulator inlet is for a 3/4 

inch gas line.  

0

  Use at least a 3/4" commercial flex hose to connect range to the gas supply (service line).

0

  A manual gas shut-off valve must be installed, in easy access in front of the gas supply (service line) and ahead of the range for   

  safety and ease of maintenance.

0

  All valves must be in the OFF position before connecting to the gas supply line.

INSTALLATION INSTRUCTIONS

   PRESSURE REGULATOR

  

0

  The regulator installed in the range is adjusted at the factory for 5" WC (natural gas) or 10” WC (L.P.) depending on the 

  customer’s request.  Regulators must not be removed.

0

  The regulator can withstand a maximum pressure of 1/2 PSIG (14" WC). If the line pressure is beyond this limit, a step-down 

  regulator will be required. 

0

  Any adjustment to regulators must be made ONLY BY QUALIFIED service personnel with proper test equipment.

   GAS REQUIREMENTS

0

  Ensure supplied gas matches the range’s gas type.

0

  Natural gas connection is 3/4" N.P.T. minimum 3/4" diameter flex line.

0

  Natural gas inlet pressure to measure 7" to 10" W.C.

0

  Propane gas connection is 3/4" N.P.T. minimum 3/4" diameter flex line.

0

  LP gas inlet pressure to measure 11" to 14" W.C.

0

  A step-down regulator is required at the LP (Propane) source to limit a pressure maximum of 14" W.C. to work with the 

  regulator provided with the LP range.

Check that all gas connections are properly sealed with a suitable gas joint compound.

   TEST All JoINTS WITh A SoAPY WATER SolUTIoN BEFoRE lIGhTING ThE BURNERS.

1.  Turn ON the manual gas valve at the inlet side of the gas supply line.

2.  Remove the kick plate by lifting and pulling away from the unit.

3.  Check for gas leaks at the flexible coupling or gas connector fitting using a solution of one part soap and three parts water.

4.  Sparingly spray or brush the soapy solution at the gas fittings; active bubbling indicates location of gas leak.

5.  If a gas leak is detected turn off the manual gas valve at the inlet side of the gas line.  Call your certified service technician.

   FlEXIBlE CoUPlINGS, CoNNECToRS AND CASTERS

0

  Flexible couplings and/or quick-disconnect fittings must be heavy duty, CSA/UL design certified of at least 3/4" NPT with 

  suitable strain reliefs.

0

  The flexible connector must comply with the standard for Connectors for Movable Gas Appliances, ANSI Z21.69-CSA 6.16  

  and any Quick-Disconnect Devices For Use With Gas Fuel Appliances should comply with ANSI Z21.41CSA 6.9.

0

  All connections must be sealed with joint compound specified for LP or Natural gas; and all connections must be tested with a     

  soapy water solution before using.

0

  When disconnection of the restraint is necessary, make sure to reconnect restraint after the range has been returned to its 

  original position.

Содержание GREEN FLAME RESTAURANT AR-GF Series

Страница 1: ...NT SERIES RANGES AR GF SERIES PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com DESIGN CLASS FUNCTION 2012 American...

Страница 2: ...________________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ______...

Страница 3: ...p the unit basic operating instructions and how to maintain that just like brand new appearance and performance over years of day to day use If you should encounter any sort of problem turn to the sec...

Страница 4: ...ric Standard Codes 5 Casters 6 Leveling 6 Electrical Connection 6 Gas Connection 7 Pressure Regulator 7 Gas Requirements 7 Test Joints 7 Couplings Connectors Casters 7 RANGE START UP PROCEDURE 8 TYPIC...

Страница 5: ...ctions for local inspectors and for future use The included Anti Tip Device must be installed prior to operation WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Страница 6: ...rtation company assumes full responsibility for the safe delivery upon acceptance of the equipment If you receive a damaged product immediately contact your delivery company your dealer your builder o...

Страница 7: ...ance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code CAN CGA B149...

Страница 8: ...re regulator B 90 Street elbow C Adapter must be 3 4 male pipe thread D Flexible connector E Manual gas shut off valve F 3 4 gas supply G Use pipe joint compound A Gas pressure regulator B 90 Street e...

Страница 9: ...a company which either in person or through a representative are engaged in and responsible for the installation of electrical wiring from the electric meter main control box or service outlet to the...

Страница 10: ...hing them to appropriate atmospheric conditions We recommend that adjustments and calibrations are performed upon installation to assure proper operation of the unit and avoid possible problems caused...

Страница 11: ...ne gas connection is 3 4 N P T minimum 3 4 diameter flex line 0 LP gas inlet pressure to measure 11 to 14 W C 0 A step down regulator is required at the LP Propane source to limit a pressure maximum o...

Страница 12: ...is best they not contribute to the taste or odor of your first oven cooking experience OVEN BURN OFF PROCEDURE Turn on the kitchen ventilating hood Light the oven according to the instructions in the...

Страница 13: ...es TYPICAL MODEL PARTS IDENTIFICATION OVEN THERMOSTAT RIGHT FRONT RIGHT REAR REAR CENTER FRONT CENTER LEFT FRONT LEFT REAR BURNER ON LIGHT FAN SWITCH IF SO EQUIPPED CONVECTION INNOVECTION ON BURNER OF...

Страница 14: ...Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been developed to assure proper installation of your oven To validate...

Страница 15: ...Strong drafts spills and general grime influence the operation of the automatic re ignition system a clean system will generally function better than a dirty system Periodically remove any materials...

Страница 16: ...ARVIEW SHOWN 1 Slide hi shelf assembly from top with mounting channels going inside the body sides 2 Set on top of support brackets and screw to body sides at rear MOUNTING CHANNEL HI SHELF ASSY RANGE...

Страница 17: ...e moisten a soft scrub cloth adding a drop of mild degreaser dish soap to create a soapy lather and wipe the griddle from left to right Clean in rows from the top to the bottom taking time to wash the...

Страница 18: ...ing process Periodic 1 Remove burner assembly and clean with warm water and wire brush Make sure the tiny burner ports are not clogged 2 Remove griddle plate assembly and thoroughly scrape and clean t...

Страница 19: ...025 36 Trim Front AR 6 7 1092 36 Tray Grease Collector 8 1194 Assy Lending Ledge 9 71475A Valve Cover Assy 10 A17036 Grate Top Singles 11 A31025 Rack AR 6 12 A99500 Door Assy AR 6 13 BASE CELL ASSY Ba...

Страница 20: ...chlorine compounds in some cleaners are corrosive to Stainless Steel Griddle Clean griddle plate with half and half mixture of soda water and vinegar Rinse with warm water Use plastic spatulas and spo...

Страница 21: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Страница 22: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Страница 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Страница 24: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Отзывы: