GAS CONNECTION

 - 

The gas inlet line size of this appliance is 3/4" NPT.  For proper operation, the gas supply service line 

must be the same size or greater than the inlet line size of the appliance.  The gas line size must not be reduced at any point along 

the supply line.

MANUAL SHUT-OFF  VALVE

 - 

A gas pressure regulator and a contractor-supplied shut-off valve must be plumbed in the gas 

service line ahead of the appliance – in a physical location where it can be reached quickly in the event of an emergency.

 Visually double check any installer-supplied intake pipes and/or blow them out using compressed air to clear any dirt or debris, 

threading chips, or other foreign matter – before installing a service line.  Those particles will clog gas orifices when gas pressure is 

applied.  Compounds used on threaded joints of this appliance piping must be resistant to the action of NG and LP gas and provide 

a gas tight seal to prevent leaks.  

The gas pressure regulator must be installed in the gas line – failure to install a pressure regulator will void the equipment 

warranty.  The regulators supplied with ranges have 3/4" NPT connections; the regulator is adjusted at the factory for 

5" W.C. (water column) manifold gas pressure (natural gas) or 10" W.C. manifold gas pressure for propane gas operation. 

Before connecting the regulator, check the incoming line pressure – as these regulators can only withstand a maximum inlet pressure 

of 14" W.C. (1/2 PSI); exceeding this pressure will damage them. If the gas supply line pressure is greater than this amount, a step-

down regulator will be required.  A gas flow direction arrow is cast into the body of the regulator to minimize installation error – it 

should point downstream to the appliance.  The blue air vent cap on the top of the regulator is part of the regulator and should not 

be removed.

Any  adjustment  to  the  regulator  must  be  made  only  by  qualified  and  licensed  service 

personnel with the proper calibrated test equipment.  Gas connections should be performed 

by a qualified licensed contractor.

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

2

Owner’s Manual

  ARRB,  AERB,  AECB,  ARKB,  ADJ,  AHS

INSTALLATION - GAS STANDARDS AND CODES

IMPORTANT - 

The installation of this appliance must conform to local codes or, in the absence of local codes, with the National Fuel 

Gas Code ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149-1, or the Propane Installation Code, CAN/CGA-B149-2 

as applicable, including:

1.  The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any 

  pressure testing of that system at test pressure in excess of 1/2 psi (3.45 kPa). 

2.  The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off 

     valve during any pressure testing of the gas supply piping system.

When installing the pressure regulator - remember it can only handle 1/2 PSI.  In 
every LPG installation, you have high source pressures, ranging from 20 PSI to 100 
PSI.  If the high pressure gas line from the LPG tank is directly connected to the unit 
without the proper step-down regulator, it will rupture the diaphragm in the valve, 
rendering it useless.

WARNING

!

A

D

C

E

F

G

C

B

B

C

G

F

E

C

D

A

H

NATURAL GAS

LP GAS

A. Gas pressure regulator

B. 90º Street elbow

C. Adapter (must be 3/4" male pipe thread)

D. Flexible connector

E. Manual gas shut-off valve

F. 3/4" gas supply

G. Use pipe-joint compound

A. Gas pressure regulator

B. 90º Street elbow

C. Adapter (must be 3/4" male pipe thread)

D. Flexible connector

E. Manual gas shut-off valve

F. 3/4" gas supply

G. Use pipe-joint compound

H. Step down regulator

Содержание ADJ

Страница 1: ...3 9898 toll free www americanrange com OWNER S MANUAL FOR PROFESSIONAL SERIES COUNTERTOP BROILERS MODEL NUMBERS ARRB AERB AECB ARKB ADJ AHS PROFESSIONAL QUALITY COOKING EQUIPMENT DESIGN CLASS FUNCTION...

Страница 2: ..._____________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date __________ Gas Ty...

Страница 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Страница 4: ...Shipping Damage Claim Procedure 1 INSTALLATION 1 3 Instructions 1 Gas Standards and Codes 2 Gas Connection 2 Manual Shut OffValve 2 Rating Plate 3 Operating 3 4 Check for Gas Leaks 3 Open Burner Gridd...

Страница 5: ...piping system during any pressure testing of that system in excess of 1 2 PSI The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during an...

Страница 6: ...The blue air vent cap on the top of the regulator is part of the regulator and should not be removed Any adjustment to the regulator must be made only by qualified and licensed service personnel with...

Страница 7: ...t adjustment screw clockwise to shut off gas to the pilots PILOT ADJUSTMENT SCREW MORE GAS LESS GAS RATING PLATE The information on the rating plate defines the model serial number gas type natural or...

Страница 8: ...RKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 4 ARRB 1 O N O F F O N O F F O N O F F O N O F F O N O F F O N O F F 2 3 4 7 8 9 10 11 12 13...

Страница 9: ...Plug 1 8 Pipe Hex Black All Manifolds 9 A29203 Pilot Tip Assembly ARRB ARRB ARKB 10242 10 A29301 Valve Dual Gas Pilot 1 8 x 3 16C 10432 11 A29004 Hood Orifice 50 1 2 Brass 11050 A29008 Hood Orifice 5...

Страница 10: ...J AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 6 AERB 23 22 21 18 17 16 15 13 14 7 4 23 O N O F F O N O F F O N O F F O N O F F O N O F F O N O F...

Страница 11: ...Quality Commercial Chrome 14 A44003 Nut Speed 6 Push Black 10601 15 A32001 Knob Gas On Off Glossy Black Flat Down 16 A80109 Valve Gas Manual On Off UL 10419 AR ARKB ARRB AECB 18 A29301 Valve Dual Gas...

Страница 12: ...Owner s Manual ARRB AERB AECB ARKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 8 AECB 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 11...

Страница 13: ...63 Manifold AECB 44 Char Broiler 2019 44 Counter Top 7 A44003 Nut Speed 6 Push Black 10601 8 A38000 Name Plate American Range 8 10499 Quality Commercial Chrome 10 A29301 Valve Dual Gas Pilot 1 8 x 3 1...

Страница 14: ...CB ARKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 ARKB 1 O F F O N O F F O N O F F O N O F F O N O F F O N O F F O N 2 3 4 5 6 7 8 9 10...

Страница 15: ...3 16C 10432 8 A44003 Nut Speed 6 Push Black 10601 10 A80154 Crumb Tray ARKB 24 1602 24 A80155 Crumb Tray ARKB 30 1602 30 A80156 Crumb Tray ARKB 36 1602 36 A80157 Crumb Tray ARKB 48 1602 48 11 A38000...

Страница 16: ...B ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 12 ADJ 22 O N O F F O N O F F O N O F F O N O F F O N O F F O N O F F 23 20 19 21 11 10 9 3 2...

Страница 17: ...Owner s Manual ARRB AERB AECB ARKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 13 ADJ 24 25 26 27 28 26 29 30 31 32 33 34...

Страница 18: ...AR ARKB ARRB AECB 14 A29004 Orifice Hood 50 1 2 Brass 11050 A29008 Orifice Hood 57 1 2 Brass 11057 A37154 Conversion Kit ADJ 48 LP Gas A37155 Conversion Kit ADJ 48 Nat Gas 15 A29301 Valve Dual Gas Pi...

Страница 19: ...cal service company to perform maintenance and repairs For ARRB AERB ADJ AHS 1 DO NOT place any char rock charcoal or woodchips inside the unit 2 DO NOT use any acidic abrasive cleaners Such cleaners...

Страница 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Отзывы: