INTRODUCTION 
 

1  Introduction and Features 

 
WALK-IN MONITORING SYSTEM 100 (WIMS 100) was designed by American Panel Corporation to 
address multiple issues regarding walk-in units and to incorporate the functionalities of various walk-in door 
devices in a single flexible, reliable, and user friendly controller. 
WIMS 100 features:  

 

Walk-in Temperature Monitoring  

 

Walk-in Temperature Alarms 

 

External Alarm Output With Direct 115VAC, Up To 150W 

 

Door Frame Heater Temperature Controlling 

 

Door Frame Heater Temperature Monitoring  

 

Electronically Controlled Light Switch With Light On/Off Indicator 

 

Automatic Light Off  

 

External Switch Connection For CAL-OSHA Back-To-Back Light Control (Optional) 

 

Celsius Or Fahrenheit Temperature Selection 

 

Real Time Clock With Backup Battery And Automatic Recharge Function  

 

1.1

 

Temperature Monitoring and Alarms 

To efficiently monitor the walk-in air temperature, WIMS 100 is equipped with a highly accurate temperature 
probe mounted inside the walk-in. The ultra bright LED display indicates the air temperature at all times. 
The controller alarm system is comprised of a high and low temperature alarm with built in trigger delay to 
allow small temperature fluctuations (occurring in daily walk-in operations such as door openings, door 
closings, and evaporator defrost cycles) without triggering the alarms. The alarm’s set points and delay times 
are fully programmable to the user’s needs. 
In case the air temperature inside the walk-in is reaching an alarm condition, WIMS 100 uses visual and audible 
alert methods. In addition to the integrated buzzer and alarm display message, the controller has a 
115V/60Hz/150W output for additional external alarm devices (optional). 
  

 

1.2

 

Door Frame Heater Temperature Control and Monitoring 

Door frame heater control and monitoring is done by two different methods that work in conjunction to save 
energy and to maintain the door frame heater temperature within a preset range. 
A temperature probe is mounted on the door frame heater wire to accurately monitor its temperature. Viewing 
the door frame heater temperature is as easy as pressing a button. 
 

1.3

 

Electronically Controlled Light Switch and Automatic Light Off 

The flexibility of WIMS 100 allows the user to operate the light from multiple locations such as multiple doors. 
The integrated light button is equipped with two LED lights to display the ON/OFF status of the light and also 
to indicate the button location in the dark. 
The Automatic Light Off feature of WIMS 100 enables the user to save energy. The amount of time the light 
will stay on can be set from 1 minute to 60 minutes, or can be set for manual shut off only. 
Back-to-back light control is provided as an optional feature. 
 
 
 

Содержание Walk-in Monitoring System 100

Страница 1: ...ner s Manual Walk in Monitoring System 100 BATT Used in UL Listed Door Panel Assemblies American Panel Corporation 5800 S E 78th Street Ocala Florida 34472 3412 Phone 352 245 7055 Fax 352 245 0726 E mail service americanpanel com ...

Страница 2: ...will ensure you years of trouble free operation On occasion situations can arise and will require the help of the factory whether it be technical information service or replacement of parts We have a highly trained Customer Service and Parts Department available to help when these situations arise We also offer a national network of service agencies that may be contacted for warranty and out of wa...

Страница 3: ...ller 3 Parameter Programming 4 Air Temperature Probe Offset 4 1 Calculating the Probe Temperature Offset 4 2 Adjust the Probe Temperature Offset 5 Change the Access Code 6 Restore the Default Settings 7 Operating WIMS 100 7 1 Turn On the Controller 7 2 Read the Walk in Air Temperature and the Current Time 7 3 Read the Door Frame Heater Temperature 7 4 Operate the Light Switch 7 5 High Alarm 7 6 Lo...

Страница 4: ...ngs door closings and evaporator defrost cycles without triggering the alarms The alarm s set points and delay times are fully programmable to the user s needs In case the air temperature inside the walk in is reaching an alarm condition WIMS 100 uses visual and audible alert methods In addition to the integrated buzzer and alarm display message the controller has a 115V 60Hz 150W output for addit...

Страница 5: ...CONTROLLER 3 2 Controller ...

Страница 6: ...e programming speed The instructions below contain screens with the exact messages displayed by the controller during the programming procedure Follow the notes located to the left of these screens Before entering the programming mode the controller has to be in the OFF state If it is not press and hold for five seconds The display will show To enter the programming mode press and hold for five se...

Страница 7: ...s and hold or to change the current time in thirty minute increments Press when done Door Frame Heater Settings The display will show This function will turn the door frame heater on or off By default the door frame heater is set to on 1 If you wish to turn the door frame heater off change the flashing value from 1 to 0 off by pressing or Press when done Note If you set the flashing value to 0 doo...

Страница 8: ...e Once the door frame heater temperature reaches this setting it will stay close to the set point according to the factory set differential Note Set the door frame heater temperature between 750 F and 1200 F Press when done The display will show Default value for coolers Default value for freezers Press or to set the percentage flashing value of the 4 minute cycle which the door frame heater will ...

Страница 9: ...ng as the controller will be on Note Press when done larm Settings High Air Alarm A The display will show Default value for freezers Default value for coolers Press or to change the flashing value representing degrees Fahrenheit If the air temperature goes above this set point the alarm will go off Press when done Alarm Settings Low Air Alarm Default value for coolers Default value for freezers Th...

Страница 10: ... The display will show Next the controller will prompt you to set the automatic light off delay The automatic light off delay is the elapsed time between the moment the user turns the light on and the moment the controller will automatically turn it off Set the automatic light off delay by pressing or to change the flashing value representing minutes The automatic light off delay can be set betwee...

Страница 11: ...ture at that particular location TMEASURED Read the air temperature on the display of WIMS 100 TWIMS 100 The temperature difference between the two temperatures is the temperature offset TOFFSET Ex Return Air Temperature measured behind the evaporator 370 F WIMS 100 Displayed Temperature 400 F The Temperature Offset will be 370 F 400 F 30 F 4 2 Adjust the Probe Temperature Offset Make sure the con...

Страница 12: ... value with the temperature offset TOFFSET calculated in the previous chapter 4 1 The temperature reading at the temperature probe will automatically be changed by the temperature offset entered When finished press The display will show Press to skip The display will show Press to skip The display will show Press to skip The display will show Press to skip ...

Страница 13: ...erican Panel Corporation is not responsible for any losses such as food spoilage resulted from misusing the air probe temperature offset 5 Change the Access Code To change the Access Code you have to enter the programming mode Follow the instructions below Before entering the programming mode the controller has to be in the OFF state If it is not press and hold for 5 seconds The display will show ...

Страница 14: ...hree dashes display The display will show The display will show Re enter the new code After successfully re entering the new code the controller will briefly display the message shown in the figure below The display will show If you wish to skip parameter programming press until you get to the OFF message To change the controller parameters see the Parameter Programming section of this manual Make...

Страница 15: ...ttings To restore the default settings press and hold and for ten seconds The display will show Press Note After restoring the default settings you may have to reprogram the controller Pay special attention to the door frame heater settings ...

Страница 16: ...me heater temperature press and hold The display will indicate the door frame heater temperature As an example see the illustration on the right When is released the controller will switch back to air temperature display 7 4 Operate the Light Switch To turn the light on press The green LED next to the light button will illuminate indicating ON status of the light To turn the light off press one mo...

Страница 17: ... the preset range 7 7 Door Switch When the door is open the display will flash the message indicated in the figure on the right 8 Error Messages Problems beyond the routine maintenance would most likely involve the refrigeration system or the control system Please contact the factory for assistance if this should occur Note that the warranty would be voided if these components are serviced by othe...

Страница 18: ...EL DIAGRAM 16 9 Electrical Diagram ...

Страница 19: ......

Страница 20: ...American Panel Corporation 5800 S E 78th Street Ocala Florida 34472 3412 Phone 352 245 7055 Fax 352 245 0726 E mail service americanpanel com ...

Отзывы: