American-Lincoln Technology
FORM NO. 56041667 - 19
7765 / 7760
HOPPER
LIFT
LEVER
HOPPER
DOOR
LEVER
P-5104
FIGURE 18
P-5105
FIGURE 19
DUST CONTROL OPERATING INSTRUCTIONS
THE VARIABLE DUMP SWEEPING AND DUST CONTROL SYSTEMS - HOW THEY WORK
Variable Dump 7765/7760 machines are equipped with a sweeping and dust control system. Figure 18 shows the highest position for
the variable dump.
The debris from sweeping is thrown into the hopper (Figure 19). The baffl e system that is built into the variable dump debris hopper is
designed to minimize dust in the air while the machine is sweeping. The impeller vacuum fan pulls the lighter dust up and through a
baffl e system. The Pre-Clean Flap separates the heavier dust particles to an area below the fi lters. The dust fi lters capture the lighter
dust particles. This allows the dust fi lters to remain cleaner and need less shaking to remove dust. When the dust fi lters become clogged
the fi lter shaker switch should be pushed to start the dust shaker cycle. This will extend the life of the fi lters.
NOTE
TURN MAIN BROOM OFF FIRST