REV. 12-28-17
American Flame: E-Stop Gas Timer
Installation
The recommended installation position is up-right as
shown in Fig 2, view "D". It has two (2) inlet and two (2)
outlet gas connections. The diagrams below provide
possible ways to plumb the E-Stop (See Fig. 3). Two (2)
½” NPT plugs are provided with the E-Stop. Plug the inlet
and outlet connections not being used for the application.
Connect gas supply to the inlet with the arrow
pointing into the valve. Connect outlet side to the gas
appliance (See Figs. 2 & 3 for details).
NOTE: Conduct a gas leak test on the E-Stop Gas Timer
after plumbing is complete.
Operation
TO TURN ON
Step 1: Rotate the clear timer dial past 20 (ESTOP1-0H) or
past 0.5 (ESTOP2-5H) to set the time. Timer will begin “ticking”
when the dial is turned while the countdown time is set.
Step 2: Turn red knob clockwise (about a ¼ turn) until it pops
outward. Gas will now flow to enable you to light the appliance.
TO TURN OFF: Let timer expire or simply press red knob
inward until it stops. The red knob will lock down with a “click”
and stop gas flow. See Fig. 4 and Fig. 5 on following page.
Note: Do not force the timer dial to the OFF position after time
is set (This will weaken the spring inside the timer body and
affect the accuracy of the time).
Timer Dial
:
Rotate clockwise to
start time. Adjust dial to
desired time frame.
Red Knob:
Turn
clockwise and knob
will “pop” up to allow
gas flow.
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
Fig. 4
E-Stop operation.
BACK VIEW
Inlet
Inlet
Outlet
Outlet
SIDE IN
SIDE OUT
BACK
IN
BACK
OUT
Fig. 2
Inlet and outlet connections.
“A-C” Shows Top View of E-Stop
“D” Shows Front View of E-Stop
Inlet
Outlet
D
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
Inlet
O
utlet
C
Inlet
Outlet
B
Inlet
O
utlet
A
Fig. 3
Plumbing options