american flame ESTOP1-0H Скачать руководство пользователя страница 3

REV. 12-28-17

American Flame: E-Stop Gas Timer

Installation

The recommended installation position is up-right as 

shown in Fig 2, view "D". It has two (2) inlet and two (2) 

outlet gas connections.  The diagrams below provide 

possible ways to plumb the E-Stop (See Fig. 3).  Two (2) 

½” NPT plugs are provided with the E-Stop.  Plug the inlet 

and outlet connections not being used for the application.  

Connect gas supply to the inlet with the           arrow 

pointing into the valve. Connect outlet side to the gas 

appliance (See Figs. 2 & 3 for details).

NOTE:  Conduct a gas leak test on the E-Stop Gas Timer 

after plumbing is complete.

Operation

TO TURN ON

Step 1: Rotate the clear timer dial past 20 (ESTOP1-0H) or 

past 0.5 (ESTOP2-5H) to set the time. Timer will begin “ticking” 

when the dial is turned while the countdown time is set.  

Step 2: Turn red knob clockwise (about a ¼ turn) until it pops 

outward. Gas will now flow to enable you to light the appliance.

TO TURN OFF: Let timer expire or simply press red knob 

inward until it stops.  The red knob will lock down with a “click” 

and stop gas flow. See Fig. 4 and Fig. 5 on following page.

Note: Do not force the timer dial to the OFF position after time 

is set (This will weaken the spring inside the timer body and 

affect the accuracy of the time).

Timer Dial

:

Rotate clockwise to 

start time.  Adjust dial to 

desired time frame.

Red Knob: 

Turn 

clockwise and knob 

will “pop” up to allow 

gas flow.

PUSH TO STOP
TURN TO START

OFF

TURN

PAST

20

40

60

MINUTES

Fig. 4

 E-Stop operation.

BACK VIEW

Inlet

Inlet

Outlet

Outlet

SIDE IN

SIDE OUT

BACK

IN

BACK

OUT

Fig. 2

 Inlet and outlet connections.

“A-C” Shows Top View of E-Stop

“D” Shows Front View of E-Stop

Inlet

Outlet 

D

PUSH TO STOP
TURN TO START

OFF

TURN

PAST

20

40

60

MINUTES

Inlet

O

utlet 

C

Inlet

Outlet

B

Inlet

O

utlet

A

Fig. 3 

Plumbing options

Отзывы: